Adjusting Images

When the camera is mounted, adjust the image settings while looking at the actual image.

Mounting the test monitor

Connect the [MONITOR] terminal of the camera to the test monitor to adjust the camera shooting direction, field angle and focus.

Pan: ±175 

TWhen configuring, turn on the power of the camera.

[MONITOR] terminal

75 K terminated

Rotation: ±175 

SPOT

SADJ

SADJ

CE

H

IRIS

EVEL

Tilt: ±70 

Shooting direction mark

Pan center mark

Rotation center mark

Rotation clasp :Make sure you hold and turn this clasp when adjusting the rotation.

Test monitor

Adjusting the camera shooting direction

This camera can be adjusted for pan, tilt and rotation. Adjust the direction and face the camera towards the object.

Note

Make sure you touch the metal surface of the [MONITOR] terminal to release the static electricity from your body. Static electricity may cause the camera to malfunction.

Memo

Rotate both pan and rotation ±175  from the positions aligned with the camera imaging direction mark, pan center mark and rotation center mark. Make sure you hold the rotation knob and adjust the rotation without holding the lens section.

After adjusting the field angle, tighten and secure the tilt fastening screw so that the field angle will not be misaligned when using the camera in locations with vigorous vibrations. (A Pg. 12)

Note

Moving the camera when it has exceeded the adjustment range may cause its performance to deteriorate.

As the tilt and rotation range of this camera is wide, part of the camera may be reflected in the shooting screen depending on the field angle and direction.

Do not hold the lens section when adjusting the camera direction. The lens section may be damaged if you apply force to it.