Using the piping hole at the side of the base to mount the camera

When the camera is not directly mounted on a ceiling, use the piping hole at the side of the base to mount the camera to the piping.

1.Remove the camera unit from the base and mount the fall-prevention wire (A Pg. 17)(A Pg. 18)

2.Wind the seal tape

Wind the joint (where the threaded portion of the piping hole and the tapped hole of the piping meets) of the piping with seal tape for more than 2 rounds.

Seal tape

3.Remove the piping hole plug of the base

Loosen the mounting screw (M3 x 6 mm) with a straight slot screw driver and pull out the plug from the side of the base.

Piping hole plug

Mounting screw

4.Mount the piping hole plug to the piping hole at the bottom of the base5.Mount the base to the piping

Screw the piping into the piping hole at the side of the base.

(Piping hole: G3/4-14 UNC)

Note

Do not screw in the piping for more than 12 mm deep. Otherwise, it may damage the internal parts of the camera.

Piping hole plug

6.The following procedures are the same as normal mounting

Cable connection (A Pg. 18)

Mounting the camera to the base (A Pg. 19)

Image adjustment (A Pg. 28)

Mounting the inner dome (A Pg. 30)

Mounting the dome cover (A Pg. 30)

23