Kenwood TS-570D instruction manual Dn Up Down/Up

Models: TS-570D

1 89
Download 89 pages 42.81 Kb
Page 82
Image 82
DN  UP DOWN/UP

APPENDIX

BC BEAT CANCEL

DN Manual backgroundManual background UP DOWN/UP

Sets or reads Beat Cancel.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

B

C

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

B

C

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

B

C

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

57 BEAT CANCEL

Microphone DOWN/UP function.

Parameter Format Parameter function

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

DN/UP

;

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BY BUSY

EX EXTENSION MENU

Reads busy signals.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

B

Y

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

B

Y

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

1 BUSY OFF/ON

Function

Sets or reads Menu.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

E

 

X

 

P1

 

 

 

P2

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

E

 

X

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

E

 

X

 

P1

 

 

 

P2

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

35

MENU

 

 

NUMBER

P2

36

MENU

 

 

SELECTION

CA CW AUTO ZERO-BEAT

FA Manual backgroundManual background FB FREQUENCY VFO A/ VFO B

Sets CW Auto Zero-Beat OFF/ON or reads status.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

C

A

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

C

A

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

C

A

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Format

Parameter function

 

 

 

P1

1

CW AUTO ZERO-

 

 

BEAT OFF/ON

 

 

 

 

 

 

Sets or reads VFO A/ VFO B frequency.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

F

A/B

 

 

 

 

 

 

P1

 

 

 

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

F

A/B

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

 

F

A/B

3

4

5

6

7

8

P1

10

11

12

13

;

 

 

 

1

2

9

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

4

FREQUENCY

CN CTCSS TONE NUMBER

FR Manual backgroundManual background FT FUNCTION RX, FUNCTION TX

Sets or reads CTCSS tone number(01~39).

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

C

N

 

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

C

N

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

C

N

 

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Format

Parameter function

 

 

 

P1

14

CTCSS TONE

 

 

NUMBER

Note:

Selecting No. 39 (1750 Hz) switches OFF the CTCSS.

Sets RX/TX (VFO A/B, memory channel).

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

F

R/T

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

F

R/T

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

F

R/T

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

3

FUNCTION

Note:

Using FR command always places the transceiver to simplex- operation status.

CT CTCSS FUNCTION

FS FINE STEP

Sets or reads CTCSS OFF/ON status.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

C

T

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

C

T

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

C

T

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Format

Parameter function

 

 

 

P1

1

CTCSS OFF/ON

 

 

 

 

 

 

Function

Fine function OFF/ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

F

S

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

F

S

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

F

S

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

1 FINE OFF/ON

76

Page 82
Image 82
Kenwood TS-570D instruction manual Dn Up Down/Up