Kenwood TS-570D instruction manual Rt Rit

Models: TS-570D

1 89
Download 89 pages 42.81 Kb
Page 85
Image 85
RT RIT

APPENDIX

PC POWER CONTROL

RC RIT CLEAR

Sets or reads transmit power.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

P

C

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

P

C

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

P

C

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

47 POWER

CONTROL

Sets the RIT frequency shift to 0.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

R

C

;

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

Note:

This command also clears the XIT frequency (same as RIT shift). The command functions independently from the RIT/XIT control.

PR SPEECH PROCESSOR

RD Manual backgroundManual background RU RIT DOWN/UP

Sets Speech Processor OFF/ON or reads status.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

P

R

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

P

R

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

P

R

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Format

Parameter function

 

 

 

P1

1

SPEECH

 

 

PROCESSOR

 

 

OFF/ON

 

 

 

 

 

 

Lowers/raises RIT frequency.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

R D/U

;

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

Note:

This command also affects the XIT frequency (same as RIT shift). The command functions independently from the RIT/XIT control.

PS POWER SWITCH

RG RF GAIN

Sets Power OFF/ON or reads status.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

P

S

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

P

S

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

P

S

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Format Parameter function

P1

1 POWER

 

OFF/ON

Sets or reads RF gain.

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

R

G

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

R

G

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

R

G

 

P1

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Format

Parameter function

 

 

 

P1

31

RF GAIN

 

 

 

 

 

 

PT CW RX PITCH

RM READ METER

Sets or reads CW RX pitch.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

P

T

 

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

P

T

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

 

P

T

3

P1

;

6

7

8

9

10

11

12

13

14

 

 

 

1

2

4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Format

Parameter function

 

 

 

P1

52

CW RX PITCH

 

 

 

 

 

 

Selects a meter function or reads meter values.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

R

M

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

R

M

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

R

M

P1

 

 

P2

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Format

Parameter function

 

 

 

P1

24

METER SWITCH

 

 

 

P2

22

METER VALUE

 

 

 

RA RF ATTENUATOR

RT RIT

Sets or reads RF ATT(attenuator).

Function

 

Set

1

2

3

4

5

6

7

8

Input

 

R

A

 

P1

;

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

 

 

 

 

 

R

A

;

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

 

 

 

 

 

R

A

 

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9 10 11 12 13 14

9 10 11 12 13 14

9 10 11 12 13 14

Parameter

Format

Parameter function

 

 

 

P1

ATTENUATOR

 

 

 

00:OFF

01:ON

Sets RIT OFF/ON or reads status.

Function

 

Set

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

Input

 

R

T

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

R

T

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

Answer

1

2

3

4

5

6

7

8

9

10

11

12

13

14

 

 

 

 

 

 

 

R

T

P1

;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Format

Parameter function

 

 

 

P1

1

RIT OFF/ON

 

 

 

 

 

 

79

Page 85
Image 85
Kenwood TS-570D instruction manual Rt Rit