4.Tighten the locking screw against the bottom collar of the 20 lb LP gas fuel tank to secure.

A

BC

A.Locking screw

B.Mounting hole

C.Bottom collar

5.Screw the gas pressure regulator/hose assembly to the 20 lb LP gas fuel tank as shown. (To disconnect, turn off the gas supply to the 20 lb LP gas fuel tank, then unscrew the gas pressure regulator/hose assembly from the 20 lb LP gas fuel tank as shown.)

connect

disconnect

B

A

A. 20 lb LP gas fuel tank

B. Gas pressure regulator/hose assembly

6.Turn on the gas supply. Wait a few minutes for gas to move through the gas line.

7.Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found.

8.Slide the tank tray back into the cabinet and lock into place.

9.The batteries are not factory installed. The 1.5-volt “D” size alkaline batteries are located in the accessory box on the grill grate. Install the batteries at this time following the instructions in the “Replacing the Batteries” section.

10.Go to “Plug in Grill” in this section.

Gas Connection to Natural Gas or Local LP Gas

WARNING

Explosion Hazard

Use a new CSA International approved “outdoor” gas supply line.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 11” (28 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with either the National Fuel Gas Code ANSI Z223.1, or CAN/CGA- B149.1 Natural Gas and Propane installation code.

Copies of the standards listed above may be obtained from:

CSA International

8501 East Pleasant Valley Rd.

Cleveland, Ohio 44131-5575

National Fire Protection Association

One Batterymarch Park

Quincy, Massachusetts 02269

1.Make gas connections.

A combination of pipe fittings must be used to connect the grill to the existing gas line.

If local codes permit, use an outdoor flexible stainless steel tubing gas connector, design-certified by CSA International, to connect the grill to the rigid gas supply line. A ⁵⁄₈" diameter line is recommended. Using a wrench to tighten, connect the gas supply to the grill. Use pipe- joint compound on all non-flared male threads. Do not kink or damage the flexible connector when moving the grill.

12