■Do not let the cord hang over the edge of a table or touch hot surfaces.
■Do not use an outdoor cooking appliance for purposes other than intended.
■When connecting, first connect plug to the outdoor cooking gas appliance then plug appliance into the outlet.
■Use only a Ground Fault Interrupter (GFI) protected circuit with this outdoor cooking gas appliance.
■Do not remove the ground prong or use with an adapter of 2 prongs.
■Use only extension cords with a 3 prong grounding plug rated for the power of the equipment and approved for outdoor use with a
NOTE: Check the circuit breaker on the back of the grill after plugging the grill into a
BB
AA
A. Rubber boot | A. Rubber boot |
B. Circuit breaker button in | B. Circuit breaker button |
“set” position | in “tripped” position |
3.Go to “Check and Adjust the Burners” section
GAS CONVERSIONS
NOTES:
■These instructions are for grill models that come equipped with the conversion kit for Local LP and Natural gas. For models that do not come equipped with the conversion kit: for conversion to Local LP order Regulator Part Number W10132702, or for conversion to Natural gas order LP to Natural Gas Conversion Kit Part Number W10118098. Use the conversion instructions included in the kit. See “Assistance or Service” section for information on ordering.
■The Fuel Remaining feature of the electronic grill display does not function with grills that are converted to Local LP (fixed piped) or Natural gas.
Tools and Parts forGas Conversion
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
IMPORTANT: Gas conversions must be done by a qualified installer. Before proceeding with conversion, shut off the gas supply to the appliance prior to disconnecting the electrical power.
This kit is designed for use from sea level up to 2000 ft elevation. For higher elevations contact KitchenAid at
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor” gas supply line.
Tools needed
■Phillips screwdriver
■Pipe wrench
■Adjustable wrench
■10 mm wrench
■6 mm socket and wrench or 6 mm nut driver
■10 mm socket and wrench or 10 mm nut driver
■Thin
■Pliers
■Pipe thread sealant certified for LP gas
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does not exceed 11” (28 cm) water column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Parts supplied
■Brass connector
■Convertible regulator 4" W.C. Natural, 11" W.C. LP
■Natural gas orifices
Failure to do so can result in death, explosion, or fire.