Product Dimensions

 

A

17¼"

17¼"

(43.8 cm)

C (43.8 cm)

B

62⁵⁄₈"

 

(158.7 cm)

 

 

28¹⁄₂"

50¹⁄₈"

(72.4 cm)

(127.2 cm)

front of

 

handle to

 

back of grill

A. 61½" (156.2 cm) on 27" (68.6 cm) models KFRS271T and KFRU271V 70½" (179.1 cm) on 36" (91.4 cm) models KFRS361T, KFRU361V, KFRS365T and KFRU365V

84½" (214.6 cm) on 36" (91.4 cm) models with side burner - KFRU368T and KFRU368V

96½" (245.1 cm) on 48" (121.9 cm) models with side burner - KFRU488T and KFRU488V

B. 27" (68.6 cm) 36" (91.4 cm) 48" (121.9 cm)

C. Not available on 27" (68.6 cm) models

14" (35.6 cm) on 36" (91.4 cm) and 48" (121.9 cm) models

Electrical Requirements

WARNING

Electrical Shock Hazard

Use only a UL listed, 14 gauge, 3 wire extension cord approved for outdoor use, marked W-A, with a maximum length of 50 ft.

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Failure to follow these instructions can result in death, fire, or electrical shock.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Check with a qualified electrician if you are not sure whether the grill is properly grounded.

A120-volt, 60-Hz, AC-only, 15-amp, fused electrical supply is required.

It is recommended that a separate circuit servicing only this grill be provided.

To avoid electrical shock, do not immerse cord or plugs in water or other liquid.

Unplug from the outlet when not in use and before cleaning. Allow to cool before putting on or taking off parts.

Do not operate any outdoor cooking gas appliance with a damaged cord, damaged plug, or after the appliance malfunctions or has been damaged in any manner. Contact the manufacturer for repair.

Do not let the cord hang over the edge of a table or touch hot surfaces.

Do not use an outdoor cooking appliance for purposes other than intended.

When connecting, first connect plug to the outdoor cooking gas appliance then plug appliance into the outlet.

Use only a Ground Fault Interrupter (GFI) protected circuit with this outdoor cooking gas appliance.

Do not remove the ground prong or use with an adapter of 2 prongs.

Use only extension cords with a 3 prong grounding plug rated for the power of the equipment and approved for outdoor use with a W-A marking.

The model/serial number rating plate is located inside the grill cabinet on the right-hand cabinet side. See the following illustration.

A

A. Model/serial number plate

Recommended Ground Method

The outdoor grill, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, or Canadian Electrical Code, CSA C22.1.

Copies of the standards listed above may be obtained from:

CSA International

8501 East Pleasant Valley Rd.

Cleveland, Ohio 44131-5575

National Fire Protection Association

One Batterymarch Park

Quincy, Massachusetts 02269

B

A

C

A. 3-prong ground plug

B. 3-prong polarized type outdoor GFI outlet

C. Ground prong

6

Page 6
Image 6
KitchenAid KFRU271VSS installation instructions Electrical Requirements, Recommended Ground Method