16
Conversion from LP Gas to Natural Gas

Installation of the regulator

1. Turn off the main gas supply valve.
2. Unplug grill or disconnect power.
3. Disconnect 20 lb LP gas fuel tank (if present).
4. Turn off all burner control valves.
5. Remove rear cover and 2 screws.
6. Use adjustable wrench to remove LP hose regulator from
brass elbow. Use adjustable wrench to remove brass elbow
from shutoff valve.
7. Apply pipe sealant to the threads of the brass connector. Use
pipe thread sealant that is certified for use with LP gas.
8. Use adjustable wrench to install brass connector (supplied) to
shutoff valve.
NOTE: The arrow on the regulator must be pointing toward
the brass connector.
9. Use pipe wrench to install the convertible regulator. Brass
cap will be facing up when tight.
10. To make sure the regulator is set for Natural gas, use
adjustable wrench to remove brass cap on appliance
regulator.
11. Examine the stem on the brass cap. If the letters “NAT” are
not showing on the end of the plastic stem farthest away from
the brass cap, remove stem from cap, turn it over and snap
stem back into the cap so the letters “NAT” are at the end of
the stem farthest away from the brass cap.
12. Reinstall cap onto convertible regulator.

Change the main grill burner valve orifices

1. Manually remove all of the grates, sear plate, and burners.
2. Remove the 2 screws that hold the burner in place. Remove
gas burner from the grill.
A.Manifold
B.Brass elbow
C.Rear of grill
D.Gas pressure regulator/hose assembly
B
A
C
D
A.Brass elbow
B.Convertible regulator
A. Two screws
A
B
NAT
A