APPENDIX D

 

DA1_U/B

D/A channel 1 unipolar or bipolar output

 

This bit specifies the output voltage of AO1 as unipolar or

 

bipolar.

 

0 means the output voltage is unipolar.

 

1 means the output voltage is bipolar.

 

DAM1 to DAM0 Analog output operation mode register

 

These two bits control the analog output operation mode.

Table D-11: Analog output operation mode

DAM1

DAM0

Meaning

 

 

 

D/A CH1

 

D/A CH0

 

 

 

 

 

 

 

 

0

0

Single Value Operation Mode

 

Single Value Operation Mode

 

 

 

 

 

0

1

Single Value Operation Mode

 

Continuous Output

 

Operation Mode

 

 

 

 

 

 

 

 

 

1

0

Continuous Output

 

Single Value Operation Mode

Operation Mode

 

 

 

 

 

 

 

 

 

 

1

1

Continuous Output

 

Continuous Output

Operation Mode

 

Operation Mode

 

 

 

 

 

 

 

 

DA_CLK

D/A clock source select register

 

 

This bit selects the D/A output pacer clock source.

 

0 means the internal clock.

 

1 means the external clock from pin AO_CLK. It is used only in continuous output operation mode.

AO_TRGF Analog output trigger flag

This bit indicates the D/A trigger event.

1 means D/A trigger event occurred from pin AO_TRG.

If you write 1 to AO_TRGF, then it acts as if D/A trigger event has occurred. This is useful for testing and debug ging. This function is applicable only in continuously output operation mode.

PCI-1712/1712L User’s Manual