The RC Configuration Software

 

 

 

Table 3: Kramer RC Configuration Window Features

 

 

 

 

 

 

 

 

 

#

 

Feature

 

 

Function

 

1

Menu Bar

 

 

Menus are described in section 6￿

 

 

Device Area

 

 

 

 

 

 

2

Name Box

 

 

Displays the name of the specific device1

 

3

Connection Box

Displays the connection properties with the device (IP address or

 

 

 

 

 

 

com port)1

 

 

4

Master Box

 

 

Select the Master device to which the slave keypad is connected.

 

 

 

 

 

 

Click the change button to change the master device type and

 

 

 

 

 

 

the Slave Keypad appearance (from a list)

 

5

Keypad Box

 

 

Select the device type2

 

 

6

Slave Keypad Tab

Shows the layout of the RC buttons according to the device type

 

 

 

 

 

 

selected, with the labels on the button. Click to Select a button to

 

 

 

 

 

 

configure, modify, read, or delete its macro.

 

 

 

 

 

 

When the button is:

 

 

 

 

 

 

 

￿ Blue rimmed, it is assigned a command sequence

 

 

 

 

 

 

￿ Green, it is selected

 

 

 

 

 

 

 

￿ Gray, it is not assigned a macro

 

7

Event Macros Tab

By default, one event command sequence is assigned and can

 

 

 

 

 

 

have commands added to it: Startup – a series of commands to be

 

 

 

 

 

 

executed upon unit startup (see Figure 18)

 

8

Button Area3

 

Label Text Box

Select a button and type the required button label

 

9

 

 

Behavior Drop-

Assign the button response to press and release actions

 

 

 

 

 

down Box

 

 

 

 

 

 

 

 

Button Definition

Behavior

 

 

 

 

 

 

 

 

 

 

 

 

Activate on Release

The macro is executed upon releasing

 

 

 

 

 

 

(default)

the button

 

 

 

 

 

 

Activate while Pressed

The macro is activated and repeated

 

 

 

 

 

 

 

 

for as long as the button is pressed

 

 

 

 

 

 

Toggle 1-2-3-4

Cycling macro behavior:

 

 

 

 

 

 

 

 

The button can be assigned with up to

 

 

 

 

 

 

 

 

4 different macros. Each time it is

 

 

 

 

 

 

 

 

pressed, the next macro in the set will

 

 

 

 

 

 

 

 

be activated in a cyclic fashion.4

 

 

 

 

 

 

Toggle Press-Release

Dual macro behavior:

 

 

 

 

 

 

 

 

One macro is activated when pressing

 

 

 

 

 

 

 

 

the button and the other is activated

 

 

 

 

 

 

 

 

when releasing the button

 

 

 

 

 

 

Disabled

The button is disabled

 

10

Write Configuration

Button5

Press to write the configuration of all the buttons to the device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 The name and IP number are initially set by the Properties dialog box (see section 7￿ .2)

2 The device type can be selected only if there is no device connected to the computer. If a device is connected, the device type is selected automatically

3 The Button area appears only after selecting a button in the Front Panel tab

4 The number of toggle states can be determined (from 1 to 4). The selected number of toggle states appears above the Button Macro area (see Figure 19)

5 This button is enabled only when a device is connected to the PC. Otherwise it is disabled

16

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Page 20
Image 20
Kramer Electronics RC-SV manual Kramer RC Configuration Window Features, Device Area