Lanier GX3000 manual Characters max -byte al None No Password Phanumerics, Auto Off

Models: GX3000

1 257
Download 257 pages 55.92 Kb
Page 218
Image 218

Monitoring and Configuring the Printer

If you set [SMTP Authentication] to [On], the printer will try logging on using only CRAM MD5. If you set [SMTP Authentication] to [Off], the printer will try logging on using PLAIN and then LOGIN.

 

Functions

Selectable value

Default

 

 

 

 

 

SMTP Authentication

Enable

Disable

 

 

Disable

 

 

 

 

 

 

SMTP Authentication Name

191 characters max. (1-byte al-

None

 

 

phanumerics)

 

 

 

 

 

 

SMTP Authentication Password

63 characters max. (1-byte al-

None (No Password)

 

 

phanumerics)

 

 

 

 

 

 

SMTP Authentication Encryption

Auto

Auto

 

 

On

 

 

 

Off

 

 

 

 

 

Specifying POP before SMTP

 

 

By specifying the SMTP authentication setting, you can send e-mails to destinations where the e-mail server carries out SMTP authentication.

By using POP before SMTP, you can log on to an SMTP server supporting POP before SMTP.

You can specify whether to use POP before SMTP, and specify the POP server name, POP port number, POP user name, and POP password.

If you set [POP Authentication Encryption] to [Auto], the printer will try logging on by APOP login, and then in plain text.

If you set [POP Authentication Encryption] to [On], the printer will try logging on only by APOP login. If you set [POP Authentication Encryption] to [Off], the printer will try logging on only in plain text.

In standby time following POP authentication (in milliseconds), you can specify how long the printer can wait for logging on to the SMTP server after logging on to the POP server.

Functions

Selectable value

Default

 

 

 

POP before SMTP

Enable

Disable

 

Disable

 

 

 

 

POP Server Name

127 characters max. (1-byte al-

None

 

phanumerics)

 

 

 

 

POP Port Number

1-65535 (1-byte numeric char-

110

 

acters)

 

 

 

 

POP User Name

127 characters max. (1-byte al-

None

 

phanumerics)

 

 

 

 

POP Password

63 characters max. (1-byte al-

None (no password)

 

phanumerics)

 

 

 

 

POP Authentication Encryption

Auto

Auto

 

On

 

 

Off

 

 

 

 

Wait Time after POP Authentica-

0-10000

300

tion

 

 

 

 

 

215