6: Line and Tunnel Settings

 

 

 

 

Tunnel Connect Mode

Description

 

Settings (continued)

 

 

Block Serial

Set whether Block Serial is enabled for debugging purposes. Choices are:

 

 

Enabled = If Enabled, incoming characters from the Serial Line will not be

 

 

forwarded to the network. Instead, they will be buffered and will

 

 

eventually flow off the Serial Line if hardware or software flow control is

 

 

configured.

 

 

Disabled = this is the default setting; incoming characters from the Serial

 

 

Line are sent on into the network. Any buffered characters are sent first.

 

 

 

 

Block Network

Set whether Block Network is enabled for debugging purposes. Choices are:

 

 

Enabled = If Enabled, incoming characters from the network will not be

 

 

forwarded to the Serial Line. Instead, they will be buffered and will

 

 

eventually flow off the network side.

 

 

Disabled = this is the default setting; incoming characters from the

 

 

network are sent on into the Serial Line. Any buffered characters are sent

 

 

first.

 

 

 

 

Email on Connect

Select an email profile number to which an email notification will be sent

 

 

upon the establishment of an accept mode tunnel.

 

 

 

 

Email on Disconnect

Select an email profile number to which an email notification will be sent

 

 

upon the disconnection of an accept mode tunnel.

 

 

 

To Configure Tunnel Connect Mode Settings

Using Web Manager

To configure the Connect Mode for a specific tunnel, click Tunnel in the menu and select Tunnel 1 -> Connect Mode.

Using the CLI

To enter the Tunnel 1 Connect Mode command level: enable -> tunnel 1 -> connect

Using XML

Include in your file: <configgroup name="tunnel connect" instance="1">

Disconnect Mode

Specifies the optional conditions for disconnecting any Accept Mode or Connect Mode connection that may be established. If any of these conditions are selected but do not occur and the network disconnects to the device, a Connect Mode connection will attempt to reconnect. However, if none of these conditions are selected, a closure from the network is taken as a disconnect.

 

Table 6-7 Tunnel Disconnect Mode Settings

 

 

 

Tunnel Disconnect

 

Description

Mode Settings

 

 

Stop Character

 

Enter the Stop Character which when received on the Serial Line, disconnects

 

 

the tunnel. The Stop Character may be designated as a single printable

 

 

character or as a control character. Control characters may be input in any of

 

 

the following forms: <control>J or 0xA(hexadercimal) or \10 (decimal).

 

 

Disable the Stop Character by blanking the field to set it to <None>.

 

 

 

EDS-MD User Guide

42

Page 42
Image 42
Lantronix EDS-MD8, EDS-MD16 To Configure Tunnel Connect Mode Settings, Tunnel Disconnect Mode Settings, Stop Character