Parameter Name: | Default |
| Parameter Value Setting | Increment | ||
|
|
|
|
|
| |
AIR HANDLER |
|
|
|
|
| |
|
|
|
|
| ||
Equipment Name | Air Handler |
| (Typewriter input screen) |
| ||
|
|
|
|
|
| |
Electric Heating Airflow |
|
|
|
| 5CFM | |
| nnnn CFM |
|
|
|
| |
Low Cooling Airflow | NOTE: CFM Default and Values Settings are dependent on the tonnage of the unit | 5CFM | ||||
SEE NOTE −. | ||||||
|
| |||||
High Cooling Airflow |
|
|
| 5CFM | ||
|
|
|
| |||
|
|
|
|
|
| |
Cooling Airflow Profile | 1 | 1: No Delays, |
| 3: ON: 82%/7.5min; OFF: No delays |
| |
2: ON: No delays; OFF: 45 sec delay | 4: ON: 50%/30s,82%/7.5min; OFF:50%/30s |
| ||||
|
|
| ||||
|
|
|
|
|
| |
Low Heating Airflow |
|
|
|
| 5CFM | |
|
|
|
|
|
| |
High Heating Airflow | nnnn CFM |
|
|
| 5CFM | |
| NOTE: CFM Default and Values Settings are dependent on the tonnage of the unit |
| ||||
Continuous Indoor Blower Airflow | 10CFM | |||||
SEE NOTE −. | ||||||
|
|
| ||||
|
|
|
|
|
| |
Humidification Airflow |
|
|
|
| 10CFM | |
|
|
|
|
| ||
Dehumidification Airflow | 70% |
| 60 to 80% (percentage of reduction of High Cooling Airflow) | 1% | ||
|
|
|
|
| ||
Heating Indoor Blower OFF Delay | 10 sec |
| 0 to 10 Seconds | 1 sec | ||
|
|
|
|
| ||
Heating Indoor Blower ON Delay | 0 sec |
| 0 to 5 Seconds | 1 sec | ||
|
|
|
|
| ||
Cooling Indoor Blower OFF Delay | 0 sec |
| 0 to 30 Seconds | 2 sec | ||
|
|
|
|
| ||
Cooling Indoor Blower ON Delay | 2 sec |
| 0 to 10 Seconds | 1 sec | ||
|
|
|
|
| ||
HP Indoor Blower OFF Delay | 45 sec |
| 0 to 60 Seconds | 5 sec | ||
|
|
|
|
| ||
HP Indoor Blower ON Delay | 0 sec |
| 0 to 30 Seconds | 5 sec | ||
|
|
|
|
|
| |
THERMOSTAT |
|
|
|
|
| |
|
|
|
|
| ||
Equipment Name |
|
| (Typewriter input screen) |
| ||
|
|
|
|
|
| |
Temp Reading Calibration | 0ºF |
|
| −5ºF to 5ºF | 1ºF | |
|
|
|
|
|
| |
Humidity Reading Calibration | 0% |
|
| −10 to 10% | 1%RH | |
|
|
|
|
|
| |
OUTDOOR EQUIPMENT |
|
|
|
|
| |
|
|
|
|
| ||
Equipment Name (HP and AC) | Outdoor Unit |
| (Typewriter input screen = up to 35 characters in string) |
| ||
|
|
|
|
| ||
Compressor Short Cycle Delay (HP and AC) | 300 Seconds |
| 60 to 300 Seconds | 60 Sec | ||
|
|
|
|
|
| |
Compressor Shift Delay On/Off (HP only) | On |
|
| On, Off |
| |
|
|
|
|
|
| |
Defrost Termination Temp (HP only) | 50ºF |
|
| 50 to 100ºF | 10ºF | |
|
|
|
|
|
|
Page 27 | icomfortt Touch Screen 7−Day Programmable Thermostat |