Alarm Codes and Troubleshooting

 

 

 

Alarm ID

Message Name

Action required to Clear/Recover

 

 

 

410

Open Low Pressure Switch

Remove any blockages or restrictions from indoor coils and/or fans. Check refrigerant charge and system operation.

 

 

 

411

Low Pressure Switch Strikes Lockout

Check system charge using approach and sub cooling temperatures. Reset by putting outdoor board in test

 

 

mode or resetting low voltage power.

 

 

 

412

Open High Pressure Switch

Check system operating pressures and compare to unit charging charts.

 

 

 

413

High Pressure Switch Strikes Lockout

Check system charge using approach and sub cooling temperatures. Reset by putting outdoor board in test

 

 

mode or resetting low voltage power.

 

 

 

414

High Discharge Line Temperature

Check system operating pressures and compare to unit charging charts.

 

 

 

415

High Discharge Line Temperature Strikes Lock-

Check system charge using approach and sub cooling temperatures. Reset by putting outdoor board in test

 

out

mode or resetting low voltage power.

 

 

 

416

Outdoor Coil Sensor Faulty

Sensor being detected open or shorted or out of temperature range. Board will not perform demand or time/tem-

 

 

perature defrost operation. (System will still heat or cool).

 

 

 

417

Discharge Sensor Faulty

The board detects open sensor or out of temperature sensor range. This fault is detected by allowing the unit to

 

 

run for 90 seconds before checking sensor resistance. If the sensor resistances not within range after 90 sec-

 

 

onds, the board will count one fault. After 5 faults, the board will lockout.

 

 

 

418

W Output Hardware Fault

Replace the control board.

 

 

 

419

W Output Hardware Fault Lockout

 

 

 

 

420

Defrost Out of Control

Defrost longer than 20 minutes. Check HP operation.

 

 

 

421

W External Miswire Alarm

Check and correct the wiring.

 

 

 

530

Damper End Switch Failed to Close

Repair/replace damper.

 

 

 

531

Damper End Switch Failed to Open

Repair/replace damper.

 

 

 

532

Damper Control Module Alarm

Check/replace if needed.

 

 

 

594

Discharge Air Temperature Sensor Problem

Check wiring. Ohm out sensor and check to temperature/resistance chart.

 

 

 

700

Comfort Sensor Temperature Sensor Problem

Recalibrate stat to clear, replace thermostat if needed.

 

 

 

701

Comfort Sensor Temperature Too High

Recalibrate stat to clear, cool down stat, adjust setpoint, replace thermostat if needed.

 

 

 

702

Comfort Sensor Temperature Too Low

Recalibrate stat to clear, warm up stat, adjust setpoint, replace thermostat if needed.

 

 

 

703

Comfort Sensor Humidity Sensor Problem

Recalibrate stat to clear, adjust setpoint, replace thermostat if needed.

 

 

 

704

Comfort Sensor Humidity Too High

Recalibrate stat to clear, replace thermostat if needed.

 

 

 

705

Comfort Sensor Humidity Too Low

Recalibrate stat to clear replace thermostat if needed.