Lennox International Inc Touch Screen Programmable Communicating Thermostat, P506052-01 Value

Models: 2P1109 Touch Screen Programmable Communicating Thermostat P506052-01

1 39
Download 39 pages 10.69 Kb
Page 29
Image 29
Manual background

 

 

Value

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter Name

Default

Min.

 

Max.

Incr.

Dependency

Note

 

 

 

 

Cooling Airflow Setting

 

 

 

 

 

 

 

 

 

High Cooling Airflow

OU tons (OUNC) *

Min CFM

 

Max CFM

25

Outdoor Unit present

1/2 HP blower

(CFM @ 100% cool)

400CFM

 

 

 

 

 

 

Min CFM

 

Max CFM

25

 

1 HP blower

 

 

 

 

 

 

 

 

 

 

 

 

Low Cooling Airflow

See Note1 below

Min CFM

 

Max CFM

25

2+ stage Outdoor Unit present

1/2 HP blower

(CFM @ lowest cool stage)

 

 

 

 

 

 

 

 

Min CFM

 

Max CFM

25

 

1 HP blower

 

 

 

 

 

 

 

 

 

 

 

 

Airflow Profile − Cooling

DIP SW

0

 

3

1

Outdoor Unit present

0–Text ID 0x0105

 

 

 

 

 

 

 

(A:ON:50%/30s,82%/7.5min

 

 

 

 

 

 

 

OFF:50%/30s)

 

 

 

 

 

 

 

1–Text ID 0x0106 (B:ON:82%/7.5min;

 

 

 

 

 

 

 

OFF: No delays)

 

 

 

 

 

 

 

2–Text ID 0x0107 (C:ON: No delays;

 

 

 

 

 

 

 

OFF: 45sec delay)

 

 

 

 

 

 

 

3–Text ID 0x0108 (D:No delays)

 

 

 

 

 

 

 

 

 

 

 

Heat Pump Airflow Setting

 

 

 

 

 

 

 

 

 

High Heat Pump Airflow (CFM @

OU tons (OUNC) *

Min CFM

 

Max CFM

25

Heat Pump present

1/2 HP blower

100%)

400CFM

 

 

 

 

 

 

Min CFM

 

Max CFM

25

 

1 HP blower

 

 

 

 

 

 

 

 

 

 

 

 

Low Heat Pump Airflow (CFM @ lowest

See Note 2 below

Min CFM

 

Max CFM

25

2+ stage Heat Pump present

1/2 HP blower

stage)

 

 

 

 

 

 

 

 

Min CFM

 

Max CFM

25

 

1 HP blower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Other Parameters

 

 

 

 

 

 

 

 

 

Equipment Name

Furnace

N/A

 

N/A

N/A

None

Up to 35 characters

 

 

 

 

 

 

 

 

Continuous Indoor Blower Airflow

DIP SW (See

Min CFM

 

Max CFM

25

None

1/2 HP blower

 

Note 3)

 

 

 

 

 

 

 

Min CFM

 

Max CFM

25

 

1 HP blower

 

 

 

 

 

 

 

 

 

 

 

 

Humidification Airflow

Same as above

Min CFM

 

Max CFM

25

Humidifier present

1/2 HP blower

 

 

 

 

 

 

 

 

 

 

Min CFM

 

Max CFM

25

 

1 HP blower

 

 

 

 

 

 

 

 

Dehumidification Airflow Percentage

140

120

 

160

2

OU present AND SC algorithm support

Percent of High Cooling Airflow

 

(=70%)

(=60%)

 

(=80%)

(=1%)

 

 

 

 

 

 

 

 

 

 

Note 1: Minimum Outdoor Unit Cooling Stage as a percentage of High Cooling Airflow (value is rounded up to the closest number on 25 CFM resolution

Note 2: Minimum Outdoor Unit Heating Stage as a percentage of High Heat Pump Airflow (value is rounded up to the closest number on 25 CFM resolution).

Note 3: All communicating Installer Parameters default CFM values based on DIP switch setting (non−communicating value) are calculated using the CFM conversion tables and rounded up to closest number on 25 CFM resolution.

Note 4: Parameter dependency − Certain parameters are dependent on others and may not be shown on the display.

Note 5: Default Values − Jumper/DIP switches impact the default value of some parameters.

Page 29

icomfortt Touch Screen 7−Day Programmable Thermostat

Page 29
Image 29
Lennox International Inc Touch Screen Programmable Communicating Thermostat, P506052-01, 2P1109 setup guide Value