TROUBLESHOOTING AND REPAIR

F-20

 

OUTPUT RECTIFIER BRIDGE TEST (continued)

FIGURE F.5 – OUTPUT RECTIFIER

LEAD 8

(—)

TO STATOR (LEAD W1)

AC1

TO POLARITY SWITCH (S2)

(+) AC2

TO RANGE SWITCH (S1)

TO CHOKE (L1)

LEAD 254

TO STATOR (LEAD S2)

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

TEST PROCEDURE

1.Remove the spark plug wires to prevent accidental engine kickback or starting.

2.WIth a 5/16” nut driver or socket, remove the 6 sheet metal screws from the case top.

3.Remove the rubber gasket (cover seal) from the lift bail.

4.Remove the fuel cap. The rubber gasket for the fill tube will come off with the case top.

5Remove the case top, then replace the fuel cap.

6.Rremove the 5 screws holding the right case side.

7.Remove the right case side by lifting up and out.

8.Conduct the test with the gasoline engine OFF.

9.Locate the Output Rectifier Bridge behind the machine case front.

10.Put the Polarity Switch in the AC Mode.

11.Unplug the 12 pin connector (J1) from the Control Board.

12.Use an Ohmter (analog meter preferred) to test the Output Rectifier per the following chart:

+ Meter Lead

— Meter Lead

Meter Reading

 

 

 

AC 1

+

LOW < 100Ω

 

 

 

+

AC 1

HIGH >1MΩ

 

 

 

AC 2

+

LOW < 100Ω

 

 

 

+

AC 2

HIGH >1MΩ

 

 

 

AC 1

HIGH >1MΩ

 

 

 

AC 1

LOW < 100Ω

 

 

 

AC 2

HIGH >1MΩ

 

 

 

AC 2

LOW < 100Ω

 

 

 

NOTE: Meter readings may vary depending on the type of meter. Typically, all “LOW” readings and all “HIGH” readings should be similar.

If any of the readings are not correct, disconnect the leads at those terminals and re-test. If still not correct, replace the Output Rectifier.

If the readings are now correct, check the leads that were disconnected for shorts or grounds.