TROUBLESHOOTING AND REPAIR | ||
| ||
|
|
|
NORMAL OPEN CIRCUIT DC WELD VOLTAGE WAVEFORM (CC MODE)
HIGH IDLE - NO LOAD - OUTPUT CONTROL AT MAXIMUM
CH1
50 volts | 5 ms |
This is the typical DC output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 50 volts and that each horizontal division represents 5 mil- liseconds in time.
Note: Scope probes connected at machine 115VAC receptacle.
SCOPE SETTINGS
Volts/Div | 50V/Div. |
Horizontal Sweep | 5 ms/Div. |
Coupling | DC |