Lincoln Electric SVM207-A service manual Normal Open Circuit DC Weld Voltage Waveform CC Mode

Models: SVM207-A

1 94
Download 94 pages 55.54 Kb
Page 74
Image 74

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-36

TROUBLESHOOTING AND REPAIR

F-36

 

 

 

 

NORMAL OPEN CIRCUIT DC WELD VOLTAGE WAVEFORM (CC MODE)

HIGH IDLE - NO LOAD - OUTPUT CONTROL AT MAXIMUM

CH1

50 volts

5 ms

This is the typical DC output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 50 volts and that each horizontal division represents 5 mil- liseconds in time.

Note: Scope probes connected at machine 115VAC receptacle.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER® 3 PHASE

Page 74
Image 74
Lincoln Electric SVM207-A service manual Normal Open Circuit DC Weld Voltage Waveform CC Mode