Lincoln Electric SVM207-A service manual Retest After Repair

Models: SVM207-A

1 94
Download 94 pages 55.54 Kb
Page 90
Image 90

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-52

TROUBLESHOOTING AND REPAIR

F-52

 

 

 

 

RETEST AFTER REPAIR

Retest a machine:

If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics.

OR

• If you repair or replace any electrical components.

ENGINE OUTPUT

Mode

No Load RPM

Load RPM

Low Idle

2200-2400

NA

High Idle

3700-3750

3100-3750

 

 

 

WELDER DC OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

Volts

 

 

Maximum

Maximum

65 - 72

21 - 26.5

205 - 240

 

 

 

 

 

WELDER AC OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

Volts

 

 

Maximum

Maximum

73 - 80

25 - 32

225 - 275

 

 

 

 

 

WELDER CV OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

Volts

 

 

Maximum

Wire Feed CV

29 - 33

19 - 23

200 - 220

 

 

 

 

 

AUXILIARY POWER RECEPTACLE OUTPUT1

 

230 Volt Receptacle

 

 

115 Volt Receptacle2

 

Open Circuit

Load Volts

 

Load Amps

Open Circuit

 

Load Volts

 

Load Amps

Voltage

 

 

 

Voltage

 

 

 

 

246 - 264

216 - 250

 

34 - 41.5

123- 132

 

115 - 130

 

17.5 - 21

 

 

 

 

 

 

 

 

 

 

FIELD AMPS AND VOLTS

 

 

 

Slip Ring Volts

 

Field Amps

32.0 - 45.0 VDC

 

6.5 - 7.5 VDC

 

 

 

1OUTPUT CONTROL set at MAXIMUM (position 10).

2Output values of each receptacle can vary within the range shown but must be within 2 volts of each other.

RANGER® 3 PHASE

Page 90
Image 90
Lincoln Electric SVM207-A service manual Retest After Repair