TROUBLESHOOTING AND REPAIR

F-52

 

 

 

 

RETEST AFTER REPAIR

Retest a machine:

If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics.

OR

• If you repair or replace any electrical components.

ENGINE OUTPUT

Mode

No Load RPM

Load RPM

Low Idle

2200-2400

NA

High Idle

3700-3750

3100-3750

 

 

 

WELDER DC OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

Volts

 

 

Maximum

Maximum

65 - 72

21 - 26.5

205 - 240

 

 

 

 

 

WELDER AC OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

Volts

 

 

Maximum

Maximum

73 - 80

25 - 32

225 - 275

 

 

 

 

 

WELDER CV OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

Volts

 

 

Maximum

Wire Feed CV

29 - 33

19 - 23

200 - 220

 

 

 

 

 

AUXILIARY POWER RECEPTACLE OUTPUT1

 

230 Volt Receptacle

 

 

115 Volt Receptacle2

 

Open Circuit

Load Volts

 

Load Amps

Open Circuit

 

Load Volts

 

Load Amps

Voltage

 

 

 

Voltage

 

 

 

 

246 - 264

216 - 250

 

34 - 41.5

123- 132

 

115 - 130

 

17.5 - 21

 

 

 

 

 

 

 

 

 

 

FIELD AMPS AND VOLTS

 

 

 

Slip Ring Volts

 

Field Amps

32.0 - 45.0 VDC

 

6.5 - 7.5 VDC

 

 

 

1OUTPUT CONTROL set at MAXIMUM (position 10).

2Output values of each receptacle can vary within the range shown but must be within 2 volts of each other.

RANGER® 3 PHASE

Page 90