WELDING PROCESS

For any electrodes the procedures should be kept with- in the rating of the machine. For electrode information see the appropriate Lincoln publication.

STICK (CONSTANT CURRENT) WELDING

Connect welding cables to the "TO WORK” and "ELECTRODE” studs. Start the engine. Set the "Polarity” switch to the desired polarity. The “RANGE” switch markings indicate the maximum current for that range as well as the typical electrode size for that range. The “OUTPUT” Control provides fine adjust- ment of the welding current within the select range. For maximum output within a selected range set the “OUT- PUT” Control at 10. For minimum output within a selected range set the “OUTPUT” Control at 5. (“OUT- PUT” Control settings below 5 may reduce arc stabili- ty) For best overall welding performance set the “RANGE” Switch to the lowest setting and the OUT- PUT” Control near the maximum to achieve the desired welding current.

 

RANGE SETTING

TYPICAL

CURRENT RANGE

 

 

ELECTRODE SIZE

 

 

90 MAX.

3/32

50 TO 90 AMPS

 

 

 

 

 

125 MAX.

1/8

70 TO 145 AMPS

 

 

 

 

 

210(DC)/225(AC)

5/32

120 TO 210(DC),

 

MAX.

 

225(AC) AMPS

 

 

 

 

The RANGER® 3 PHASE can be used with a broad range of AC and DC stick electrodes. See “Welding Tips 1” included with the RANGER 3 PHASE for elec- trodes within the rating of this unit and recommended welding currents of each.

TIG (CONSTANT CURRENT) WELDING

The K930-[ ] TIG Module installed on a RANGER 3 PHASE provides high frequency and shielding gas control for AC and DC GTAW (TIG) welding processes. The TIG Module allows full range output control. After flow time is adjustable from 0 to 55 seconds.

When using the RANGER® 3 PHASE for AC TIG weld- ing of aluminum, the following settings and electrodes are recommended:

SETTINGS FOR PURE TUNGSTEN

TUNGSTEN

RANGE SWITCH

APPROXIMATE

DIAMETER (in.)

SETTINGS

CURRENT RANGE

 

 

 

 

 

 

 

1/8

90

or

145

80

-

150 Amps

3/32

90

or

145

45

-

130 Amps

1/16

 

90

 

40 -

80 Amps

 

 

 

 

 

 

 

SETTINGS FOR  1% THORIATED TUNGSTEN

TUNGSTEN

RANGE SWITCH

APPROXIMATE

DIAMETER (in.)

SETTINGS

CURRENT RANGE

 

 

 

 

 

1/8

90, 145, or 210

80

-

225 Amps

3/32

90 or 145

50

-

180

Amps

1/16

90 or 145

45

-

120

Amps

 

 

 

 

 

 

The K930-[ ] TIG Module should be used with the RANGER® 3 PHASE on high idle to maintain satisfac- tory operation. It can be used in the AUTO position but the delay going to flow idle after welding is ceased will be increased if the AFTER FLOW CONTROL is set above 10 seconds.

WIRE FEED WELDING PROCESSES (CONSTANT VOLTAGE)

The Innershield® electrode recommended for use with the RANGER 3 PHASE is NR®-212-MP. The electrode sizes and welding ranges that can be used with the RANGER® 3 PHASE are shown in the following table:

Diameter

Wire Speed

Approximate

(in.)

Range In./Min.

Current Range

 

 

 

 

.035

80

- 110

75A to 120A

.045

70

- 130

120A to 170A

.068

40

- 90

125A to 210A

 

 

 

 

The RANGER® 3 PHASE is recommended for limited “MIG” welding (GMAW - gas metal arc welding). The recommended electrodes are.030” and .035”SuperArc L-50 and L-56. They must be used with a blended shielding gas such as C25 (75% Argon - 25% CO2). The welding ranges that can be used with the RANGER 3 PHASE are shown in the following table:

Diameter

Wire Speed

Approximate

(in.)

Range In./Min.

Current Range

 

 

 

 

.030

80

- 110

75A to 120A

.035

70

- 130

120A to 170A

 

 

 

 

ARC GOUGING

The RANGER® 3 PHASE can be used for limited arc gouging.

Set the Range switch to adjust output current to the desired level for the gouging electrode being used according to the ratings in the following table:

CARBON DIAMETER (in)

CURRENT RANGE (DC, electrode positive)

 

 

1/8

30 - 60 Amps

5/32

90 - 150 Amps

3/16

200 - 250 Amps

 

 

RANGER® 3 PHASE