TROUBLESHOOTING AND REPAIR

F-5

 

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

No weld output in AC or DC Modes.

1.

Check

the

welding

cables,

1. Disconnect lead W1 from the

The auxiliary power (480, 23 &

 

clamps and electrode holder for

Output Bridge (D1) and check

115VAC) is normal. Engine runs

 

loose or broken connections.

for the presence of 80VAC from

normally.

2.

Check

the open circuit

voltage

lead W1 to lead W2 on the main

 

stator winding. See the Wiring

 

 

(OCV) at the welder output termi-

 

 

Diagram.

If the AC voltage is

 

 

nals, engine

at high idle (3650

 

 

NOT present, the winding in the

 

 

RPM). Normal maximum is 73 to

 

 

stator may be faulty. Check the

 

 

80VAC. Normal DC maximum is

 

 

winding for continuity and test to

 

 

67 to 72VDC. If the OCV is OK

 

 

be sure it is NOT grounded to

 

 

then proceed to Step #2.

 

 

 

 

the stator iron. Replace the

 

 

 

 

 

 

 

 

 

 

 

 

Sstator if necessary. If the cor-

 

 

 

 

 

 

rect AC voltage is present, pro-

 

 

 

 

 

 

ceed to step #2.

 

 

 

 

 

 

2. Check the Reactor, Range

 

 

 

 

 

 

Switch (S1) and associated

 

 

 

 

 

 

wires for loose or faulty connec-

 

 

 

 

 

 

tions. Check the reactor wind-

 

 

 

 

 

 

ing for continuity and test to be

 

 

 

 

 

 

sure it is NOT grounded to the

 

 

 

 

 

 

reactor iron.

 

 

 

 

 

 

3. Check the Choke (L1), Polarity

 

 

 

 

 

 

Switch (S2) and associated

 

 

 

 

 

 

wires for loose or faulty connec-

 

 

 

 

 

 

tions. Check the choke winding

 

 

 

 

 

 

for continuity and test to be sure

 

 

 

 

 

 

it is NOT grounded to the choke

 

 

 

 

 

 

iron.

 

 

 

 

 

 

 

4. Check the weld output terminals

 

 

 

 

 

 

and associated wires for loose

 

 

 

 

 

 

or faulty connections.

 

 

 

 

 

 

5. Perform the Output Bridge

 

 

 

 

 

 

Test.

 

 

 

 

 

No DC welding output. AC welding

1.

Make sure the Polarity Switch is

1. Perform the Output Bridge Test.

output and auxiliary power is nor-

 

in the proper position and is

2. Check the

Choke (L1), the

mal.

 

 

“seated” correctly.

 

Polarity Switch (S2) and associ-

 

 

 

 

 

 

 

2. Make

sure

the electrode and

ated wires for loose or faulty

 

 

polarity are correct for the

connections. Check the choke

 

 

process being used.

 

winding for continuity and test to

 

 

 

 

 

 

be sure it is NOT grounded the

 

 

 

 

 

 

choke iron.

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.