LINDY CPU IP Access Switch

User Manual

IP Address:

The unit can either have its IP address assigned dynamically at bootup (DHCP), or it can be given a fixed IP address.

For dynamic IP address assignment, select the Obtain an IP address automatically, radio button.

To specify a fixed IP address, select the Set IP address manually, radio button and fill in the information required.

Note: A fixed IP address can also be assigned with the ARP command as follows:

arp -s <ip address> <CPU IP ACCESS SWITCH’s MAC address>

For example,

arp -s 10.0.0.10 00-48-54-65-00-01

assigns an IP address of 10.0.0.10 to a CPU IP ACCESS SWITCH with a MAC address of 00-48- 54-65-00-01

Log Server:

Important transactions that occur on the CPU IP ACCESS SWITCH, such as logins, internal status messages, etc., are kept in an automatically generated log file. Specify the MAC address and a Port number for the server you want the log file to reside on in the Log Server section.

Note: The Log Server port number must be different from the port numbers that were specified for Program and Java in the Access Ports section.

The Log Server is discussed in detail in Chapter 6.

16

Page 20
Image 20
Lindy 39401 user manual IP Address, Log Server