LINDY CPU IP Access Switch User Manual 22 Customization
An explanation of the customization settings is given in the table, below:
Uploads After obtaining new versions of the firmware, specify the directories that you
have put them in here to start the firmware upgrade procedure (see p. 23 for
details).
Time out Control If the CPU IP ACCESS SWITCH doesn’t receive any input from the computer
that currently has access to it for the amount of time specified here, it ends
the connection so it can be available for other users.
Login failure
Login failures allowed, sets the number of consecutive failed login attempts
that are permitted from a remote computer. Login failure timeout, sets the
amount of time a remote computer must wait before attempting to login again
after it has exceeded the number of allowed failures
Working Modes
If Stealth Mode is enabled, the CPU IP ACCESS SWITCH cannot be pinged.
If Echo Mode is disabled, the CPU IP ACCESS SWITCH will not show up in
the list of local CPU IP ACCESS SWITCH units (see p. 11 and p. 27)
Reset on exit
Placing a check here causes the CPU IP ACCESS SWITCH to reset itself and
implement all the new changes when you Click OK and close the Settings
Notebook. Otherwise settings changes will not take effect until the CPU IP
ACCESS SWITCH is manually reset.