A794 Owner’s Guide | Chapter 6: Programming Information |
Select Sensors to Stop Printing
ASCII | ESC c 4 n |
Hexadecimal | 1B 63 34 n |
Decimal | 27 99 52 n |
Value of n: | Sensor status |
Sensor Status
Bit | Sensor | 0 | 1 |
0 | Receipt Paper | Disabled | Enabled |
1 | Receipt Paper | Disabled | Enabled |
Undefined |
|
| |
6 | Undefined |
|
|
Bits 5 and 7 are not used.
Default: 0
Determines which sensor stops printing on the respective station. The command does not affect the paper out status on the receipt station, which will automatically stop the printer when the paper is depleted.
Enable or Disable Panel Button
ASCII | ESC c 5 n | |
Hexadecimal | 1B 63 35 n | |
Decimal | 27 99 53 n | |
Value of n: | 0 | = Enable |
| 1 | = Disable |
Default: | 0 | (Enable) |
Enables or disables the Paper Feed Button. If the last bit is 0, the Paper Feed Button is enabled. If the last bit is 1, the Paper Feed Button is disabled.
Exceptions
Functions that require the Paper Feed Button (except for the Execute Macro [1D 5E] command) cannot be used when it has been disabled with this command.
December 1999 | 65 |