M-S Cash Drawer A794 Select Paper Sensors to Output Paper End Signals, Range of n, Default of n

Models: A794

1 147
Download 147 pages 61.87 Kb
Page 69
Image 69

Chapter 6: Programming Information

A794 Owner’s Guide

Select Paper Sensors to Output Paper End Signals

ASCII

ESC c 3 n

Hexadecimal

1B 63 33 n

Decimal

27 99 51 n

Value of n:

If either bit 0 or bit 1 is on, the paper roll near-end sensor is selected as the paper sensor outputting paper-end signals.

If either bit 2 or bit 3 is on, the paper roll end sensor is selected as the paper sensor outputting paper-end signals.

Bit

Position

Hex

Decimal

Function

0

Off

00

0

Paper roll near-end sensor disabled

 

On

01

1

Paper roll near-end sensor enable

1

Off

00

0

Paper roll near end sensor disabled

 

On

02

2

Paper roll near end sensor enabled

2

Off

00

0

Paper roll end sensor disabled

 

On

04

4

Paper roll end sensor enabled

3

Off

00

0

Paper roll end sensor disable

 

On

08

8

Paper roll end sensor enabled

4, 5, 6, 7

-

-

-

Undefined

Range of n:

1-255

 

 

 

Default of n: 12

Specifies the paper sensor to output a paper end signal. Multiple sensors may be selected to signal when paper has run out. When multiple sensors have been selected, anytime one of the sensors detects a paper end, the paper end signal is output.

When this command is executed a sensor is switched. The paper end signal switching is delayed depending on the receive buffer state.

Exceptions

This command can only be used with a parallel interface.

The command is ignored if it used with a serial interface.

64

December 1999

Page 69
Image 69
M-S Cash Drawer A794 manual Select Paper Sensors to Output Paper End Signals, Range of n, Default of n