9.3.5.4. Putting Foot Rubber

<FIG1>

Safety Work

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not pressurize the concave

 

Do not go out of the rib

 

Bottom Case part

 

heaven side

 

(Sheet concave measures).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom BATT Sheet

Adjust the inclination of the direction of the length hand to 0.2 or less

<Notes and procedures when rubber foot / rubber foot (center) putting>

1)Wipe rubber foot/ rubber foot (center) pasting side with the dry cloth (3 places)

(Cautions) - Exchange the cloth (rag) wiped off regularly (twice / day)

2)A rubber foot/rubber foot(center) pasting

(Cautions) - Put on the Bottom Case with tweezers etc.

- Paste so as not to touch the sticking side.

3)Pressurizing (treatment device use) condition: Pressurizing power : 2.5kgf or more, Time : 3 seconds or more

Safety Work

Safety Work

Foot Rubber Support

Affixes to the concave part.

Pressurizing treatment device use

Screw Installation (XSB2+4FNL)

(Attention)

-Please work after installs in the treatment device when you tighten the screw.

Foot Rubber

Affixes to the concave part. Pressurizing treatment device use

Safety Work

Foot Rubber Support Affixes to the concave part. Pressurizing treatment device use

Safety Work

Bottom BATT Sheet

Put on the rib side

Ref to FIG 1

Work with a specified treatment device when you pressurize Foot Rubber and Bottom BATT Sheet .