Power Supply management

POE management

￿Port Enable: displays the POE port status. Y means the port is enabling. N means the port is disabling and will not have any power providing but the port still can transmit the data packet.

￿PwrLimitClass.: displays the power class limit status. N means the power class limit is disabling. Y means the power class limit is enabling. The power limit class will follow the value that set in the power limit max when is enabling.

￿PwrLimitManag.: displays the POE management that will follow or will not following the priority rules.

￿Detect Legacy: The legacy detection is to identify the PD devices with unique electrical signatures, that did not follow the IEEE 802.3af standard.

￿Priority: the port priority for power supply’s priority. 1 = C (critical), 2 = H (High), 3 = L (Low).

￿PowerLimitMax: per port power output to PD’s power limit.

￿Fault Status: display the PD error status message. There are three error status and explain as following.

￿Null: It means there is no PD connected or the connected PD device status is normal.