Device Information interface

IP Configuration

You can configure the IP for this switch. The system has the default IP address. You can re-configure or use the default value.

1.Select the <Edit>

2.DHCP Client: “Enable” is to get IP from DHCP server. “Disable” is opposite. The DHCP client function only works if you haven't assigned a static IP address that different than the switch default IP. Once the default IP has been changed the DHCP will not effective and the switch will continue using the manually entered static IP. If you have changed the switch to a static IP address, you can set the IP address back to its default IP address or you can reset the switch back to factory default. And then you can enable the DHCP client function to work.

3.IP Address: assign the switch IP address. The default IP is 192.168.16.1.

4.Subnet Mask: assign the switch IP subnet mask.

5.Gateway: assign the switch gateway. The default value is 192.168.16.254.

6.Select <Apply> action to apply the configuration.

[Note] Always restart the switch after finished the setup to apply the new IP setting.