.A complete Parts List is available at www.MillerWelds.com
OM-217 455 Page 28
8-3. Battery Charge Cable Connections
!Stop engine.
!Do not charge a battery which has
loose terminals or one showing
damage such as a cracked case or
cover.
!Have only qualified persons do bat-
tery charging work.
!Keep cables away from moving
parts.
!Do not use damaged cables.
!Be sure charger output voltage
matches battery voltage.
!Read BCI Battery Service Manual
before charging.
.Before connecting to battery, place
Charge Voltage switch in position
matching voltage of battery being
charged.
1 Battery
2 Battery Charging Cables
Use less than 20 feet (6.1 m) of AWG #1 or
larger cable.
3 Terminal Lug
Use lugs of proper amperage capacity and
hole size for connecting to charge output
terminals.
Install suitable connectors on remaining
ends of battery cables.
4 Battery Charge Positive (+) Output
Terminal
5 Battery Charge Negative () Output
Terminal
.Connect charging cables to battery
charge output terminals before con-
necting to battery terminals.
Connect Battery Charge Positive (+) cable
to battery positive (+) terminal, and battery
Charge Negative () cable to battery nega-
tive () terminal.
Ref. 228 649-A / Ref. 804 397-A / S-0714
+
1
3
4
5
2
3