. A complete Parts List is available at www.MillerWelds.com
8-4. Battery Charging Procedure
In Example:
Battery Voltage = 12 Volts
Battery CCA Rating = 500
Charge Current = 100 A (See Section
Coarse Range Setting = 60 to 140 A
V/A Control Setting = 50%
Stop Engine.
Determine Charge Current From
Battery CCA Rating And Chart
(See Section
Turn Off Battery Charging
Switch.
Set Charge Voltage Switch To
Voltage Of Battery Being
Charged (12, 24, Or 36 Volt).
NOTICE − Do not switch under load.
Set Coarse Range Switch And
Fine Control To Obtain Correct
Charging Current.
NOTICE − Do not switch under load.
Set Weld Process Switch To
Charge Position.
−
+
Connect Cables (Observe
Correct Polarity).
Start Engine. |
| Turn On Battery |
| Charge 10 |
| Stop Engine. |
| Charge 10 minutes. |
|
|
|
| |||||
|
|
|
| |||||
|
| Charging Switch. |
| Minutes |
|
|
| Check Battery Voltage. |
|
|
|
|
|
|
|
| Continue Charging If |
|
|
|
|
|
|
|
| Necessary. |