.A complete Parts List is available at www.MillerWelds.com

9-2. Maintenance Label And Engine Maintenance Activities

6

5

7

3

2

4

3

! Stop engine and let cool.

Oil And Fuel

1Oil Drain Valve

2Oil Filter

Change engine oil and filter according to en- gine manual.

NOTICE − Close valve and valve cap before adding oil and running engine.

Fill crankcase with new oil to full mark on dip- stick (see Section 5-4).

3 Fuel Lines

Replace fuel lines if cracked or worn.

4Inline Fuel Strainer Install new filter as shown.

7

5 Fuel Filter

Replace filter according to engine manual. Wipe up any spilled fuel.

Start engine, and check for fuel leaks.

! Stop engine, tighten connections as necessary, and wipe up fuel.

Coolant

6Radiator Cap

7Radiator Drain Cocks (One located on bottom of radiator)

Drain engine coolant according to proce- dure in engine manual.

8

1

Add engine coolant as follows:

8 Thermostat Housing Plug

Remove thermostat housing plug. Add cool- ant to radiator until coolant is at bottom of fill- er neck and coolant trickles out of thermo- stat housing plug hole. This ensures all air is purged from the system.

Reinstall plug and radiator cap. Check cool- ant level in overflow bottle.

Engine coolant is a mixture of water and ethylene glycol base antifreeze. A solution of 50% antifreeze and 50% water must be used in this engine. Do not use 100% anti- freeze or severe damage will occur.

OM-217 455 Page 32

Page 36
Image 36
Miller Electric 250 manual Maintenance Label And Engine Maintenance Activities, Stop engine and let cool Oil And Fuel