.A complete Parts List is available at www.MillerWelds.com
OM-217 455 Page 15
5-2. Installing Exhaust Pipe
804 196-A / Ref. 228 647-A
!Stop engine and let cool.
!Do not blow exhaust toward
right side of unit where air inlet
is or air cleaner may require
frequent service. Point ex-
haust pipe in desired direction
but always away from front
panel and direction of travel.
Tools Needed:
1/2 in
5-3. Connecting the Battery
804 250-A / Ref 228 647 / Ref. S-0756-D
1/2 in
Tools Needed:

+

!Connect negative ()
cable last.