.A complete Parts List is available at www.MillerWelds.com

5-3. Timers

1

2

3

4

5

6

8

9

7

Ref. 213 935-A

To enter the TIMERS (5) menu depress the SETUP (6) button 4 times or until the TIMERS light (5) is illuminated.

Items that can be adjusted in this menu are:

Run-in speed (R-IN) − The speed of the wire prior to the welding arc being struck. This setting is a percentage of the Wire Feed Speed the unit is set to for welding. Programming value ranges from 25-150.

Preflow (PRE) − The amount of time that the shielding gas will flow after the trigger is

depressed and before the welding arc will be allowed to be active. Range of setting is from 0-5 seconds.

Postflow (POST) − The amount of time that the shielding gas will flow after the arc has been shut off. Range of setting is 0-10 seconds.

Spot Timer (SPOT) − The amount of time that the arc will be active before it shuts off automatically. Range of setting is from 0-120 seconds. Spot timer is reset upon re- lease of welding gun trigger.

Display (DISP) − Allows the Wire Speed display to show actual welding amperage while arc is active and for 5 seconds after arc is shut off. Setting is either AMPS or WFS for standard Wire Feed Speed.

Once in the TIMERS (5) menu, rotate the left knob (8) to find a particular item, and ro- tate the right knob (9) to change setting or status.

Depress SETUP (6) button to get out of TIMERS (5) menu and to enter welding mode.

OM-1327 Page 32

Page 36
Image 36
Miller Electric 350, 350P, Millermatic 350 manual Timers