.A complete Parts List is available at www.MillerWelds.com

6-3. Measuring Input Capacitor Voltage

3

1

 

!

Significant DC voltage can

 

 

remain on capacitors after

 

 

unit is Off. Always check ca-

 

 

pacitors as shown to be sure

 

 

they have discharged before

 

 

working on unit.

3

Turn Off welding power source and

disconnect input power.

 

 

Remove case.

 

1

Input Capacitor C3 Terminals

2

2

Input Capacitor C4 Terminals

 

3

Voltmeter

 

Check input capacitors as shown.

 

Measure the dc voltage across the

 

positive (+) and negative (−)

 

terminals until voltage drops to near

 

0 (zero) volts.

 

Proceed with job inside unit.

 

Reinstall case when finished.

Tools Needed:

5/16 in

221 044-A / Ref. 803 550-A

OM-1327 Page 42

Page 46
Image 46
Miller Electric 350, 350P, Millermatic 350 Measuring Input Capacitor Voltage, Significant DC voltage can, Working on unit