.A complete Parts List is available at www.MillerWelds.com
OM-1327 Page 40
.W elding wire birdnesting at the welding power source drive rolls may occur if this value is set too high.

5-10. Set Up Push Motor Torque (SUP) Or Reset (rES)

1 Setup Button
2 Left Knob
3 Left Display
4 Right Knob
5 Right Display
6 Arc Control Button
Simultaneously press Setup and Arc Control
buttons w hile t ur ning o n u nit input p ower a t
the power switch.
Rotate the left knob counterclockwise
(CCW) t o f i n d t h e p a r t i c u l a r i t e m , a n d r o t a t e
the right knob to change the setting.
The following items can be adjusted by
rotating the left knob counterclockwise
(CCW):
Set up Push Motor Torque (SUP) − This
feature is only active when a push/pull gun
is connected to the welding power source.
The (SUP) setting will adjust the
over-torque limit of the push motor inside
the welding power source. The range is
0-250 and the default value is 130.
Increasing this setting will increase the
over-torque limit and speed up the remote
wire feed speed motor.
.If Aluma-Pro push/pull gun has a
listed SUP value, set the power
source to match the SUP value.
To save settings and exit the (SUP) menu,
depress the gun trigger.
Reset (rES) − Rotate the right knob to
select ON. Press and release gun trigger to
reset system to factory default values.
5
Ref. 213 935-A
4
2
1
3
6