PARAMETERS

Func-

Parameter

 

 

Minimum

 

Refer To

Name

Setting Range

Setting

Factory Setting

Page:

tion

Number

 

 

Increments

 

<Note9>

 

 

 

 

 

functions

52

DU/PU main display data selection

0, 5 to 14, 17, 18, 20,

1

0

67

23, 24, 25, 100

 

 

 

 

 

 

53

PU level display data selection

0 to 3, 5 to 14, 17, 18

1

1

67

 

54

FM terminal function selection

1 to 3, 5 to 14,

1

1

67

Display

17, 18, 21

 

 

 

 

 

55

Frequency monitoring reference

0 to 400Hz

0.01Hz

Rated output

69

 

60Hz<50Hz>

 

56

Current monitoring reference

0 to 3600A

0.1A

current

69

 

 

 

 

 

 

Automatic restart functions

57

Restart coasting time

0 to 30 sec, 9999

0.1 sec

9999

70

 

 

 

 

 

 

 

 

 

58

Restart cushion time

0 to 60 sec

0.1 sec

1.0 sec

70

 

 

 

 

 

 

 

Additional function

59

Remote setting function selection

0, 1, 2

1

0

72

 

 

 

 

 

 

 

 

 

60

Intelligent mode selection

0 to 8

1

0

73

 

61

Reference I for intelligent mode

0 to 3600A, 9999

0.1A

9999

75

 

*62

Ref. I for intelligent mode accel.

0 to 150%, 9999

0.1%

9999

75

 

*63

Ref. I for intelligent mode decel.

0 to 150%, 9999

0.1%

9999

75

 

64

Starting frequency for elevator mode

0 to 10Hz, 9999

0.01Hz

9999

75

functions

65

Retry selection

0 to 5

1

0

76

66

Stall prevention operation level

0 to 400Hz

0.01Hz

60Hz<50Hz>

77

 

 

reduction starting frequency

 

 

 

 

 

 

 

67

Number of retries at alarm occurrence

0 to 10,101 to 110

1

0

76

selection

68

Retry waiting time

0 to 10 sec

0.1 sec

1 sec

76

69

Retry count display erasure

0

⎯⎯

0

76

 

 

70

Special regenerative brake duty

0 to 100%

0.1%

0%

77

Operation

71

Applied motor

0 to 8, 13 to 18

1

0

78

74

Filter time constant

0 to 8

1

1

81

 

72

PWM frequency selection

0, 1, 2

1

1

79

 

73

0-5V/0-10V selection

0 to 5, 10 to 15

1

1

80

 

 

 

 

 

 

 

 

75

Reset selection/disconnected PU

0 to 3, 14 to 17

1

14

81

 

detection/PU stop selection

 

 

 

 

 

 

 

76

Alarm code output selection

0, 1, 2, 3

1

0

83

 

77

Parameter write disable selection

0, 1, 2

1

0

84

 

78

Reverse rotation prevention selection

0, 1, 2

1

0

85

 

79

Operation mode selection

0 to 8

1

0

86

 

80

Motor capacity

0 to 3600kW, 9999

0.1kW

9999

89

 

81

Number of motor poles

2, 4, 6, 12, 14, 16, 9999

1

9999

89

 

82

Motor exciting current (Note 6)

0 to , 9999

1

9999

90

constants

*83

Rated motor voltage

0 to 1000V

0.1V

575V

90

90

Motor constant (R1) (Note 6)

(Note 6)

(Note 6)

9999

90

 

84

Rated motor frequency

50 to 120Hz

0.01Hz

60Hz<50Hz>

90

 

89

Speed control gain

0 to 200%

0.1%

100%

89

Motor

 

 

 

 

 

 

91

Motor constant (R2) (Note 6)

(Note 6)

(Note 6)

9999

90

 

 

92

Motor constant (L1) (Note 6)

(Note 6)

(Note 6)

9999

90

 

93

Motor constant (L2) (Note 6)

(Note 6)

(Note 6)

9999

90

 

94

Motor constant (X) (Note 6)

(Note 6)

(Note 6)

9999

90

 

95

Online auto tuning selection

0, 1

1

0

96

 

96

Auto tuning setting/status

0, 1, 101

1

0

90

 

100

V/F1 (first frequency) (Note 1)

0 to 400Hz, 9999

0.01Hz

9999

98

flexiblepoint V/F characteristics

101

V/F1 (first frequency voltage)

0 to 1000V

0.1V

0

98

V/F3 (third frequency) (Note 1)

104

0 to 400Hz, 9999

0.01Hz

9999

98

 

 

(Note 1)

 

 

 

 

 

102

V/F2 (second frequency) (Note 1)

0 to 400Hz, 9999

0.01Hz

9999

98

 

103

V/F2 (second frequency voltage)

0 to 1000V

0.1V

0

98

 

(Note 1)

 

 

 

 

 

 

5-

 

 

 

 

 

 

105

V/F3 (third frequency voltage) (Note 1)

0 to 1000V

0.1V

0

98

 

 

106

V/F4 (fourth frequency) (Note 1)

0 to 400Hz, 9999

0.01Hz

9999

98

19

Page 29
Image 29
Mitsubishi Electronics FR-A500L instruction manual 17, 18