SPECIFICATIONS

 

Display on

Operating

 

status

 

operation panel

 

 

 

FR-DUO4 or

 

 

parameter unit

 

Display

FR-PU04

Alarm

 

definition

 

Operating

 

 

 

Additional

status

 

display on

Alarm

 

parameter unit

 

(FR-PU04)

definition

 

only

Interactive

 

 

 

 

guidance

Protective/alarm functions

Environment

Ambient temperature (1)

Ambient humidity

 

 

Storage temperature (2)

 

Ambience

 

Altitude, vibration

 

 

Selection can be made from output frequency, motor current (steady or peak value), output voltage, frequency setting, running speed, motor torque, converter output voltage (steady or peak value), electronic overcurrent protection load factor, input power, output power, load meter, motor exciting current, cumulative energization time, actual operation time, watt-hour meter, regenerative brake duty and motor load factor.

Alarm definition is displayed when protective function is activated. 8 alarm definitions are stored.

(Four alarm definitions are only displayed on the operation panel.)

Input terminal signal states, output terminal signal states, option fitting status, terminal assignment status

Output voltage/current/frequency/cumulative energization time

immediately before protective function is activated

Operation guide and troubleshooting by help function

Overcurrent shut-off (during acceleration deceleration, constant speed) regenerative overvoltage shut-off, undervoltage, instantaneous power failure, overload shut-off (electronic overcurrent protection), ground fault overcurrent, stall prevention, overload warning, fin overheat, option error, parameter error, PU disconnection, No. of retries over, output open phase, CPU error, 24VDC power supply output short circuit, operation panel power supply short circuit, main circuit error

10°C to +40°C (non-freezing)

90%RH or less (non-condensing)

20°C to +65°C

Indoors. (No corrosive and flammable gases, oil mist, dust and dirt.)

Max. 1000m (3280.80 feet) above sea level, 5.9m/s2 {0.6G} or less (conforms to JIS C 0911)

Note: 1. For FR-A560L-375K, 450K at constant torque (CT) rating maximum ambient temperature can be 50°C (122°F).

2. Temperature applicable for a short period in transit, etc.

43

Page 55
Image 55
Mitsubishi Electronics FR-A500L instruction manual Temperature applicable for a short period in transit, etc