PARAMETERS

Func-

Parameter

 

 

Minimum

 

Refer To

Name

Setting Range

Setting

Factory Setting

Page:

tion

Number

 

 

Increments

 

<Note9>

 

 

 

 

 

Current detection

150

Output current detection level

0 to 200%

0.1%

150%

120

151

Output current detection period

0 to 10 sec

0.1 sec

0

120

 

 

152

Zero current detection level

0 to 200%

0.1%

5.0%

121

 

153

Zero current detection period

0 to 1 sec

0.01 sec

0.5 sec

121

functions

154

Voltage reduction selection during stall

0, 1

1

1

121

prevention operation

 

 

 

 

 

 

 

 

 

 

 

 

155

RT activated condition

0, 10

1

0

122

 

*156

Stall prevention operation selection

0 to 31 (Odd), 100

1

0

122

Sub

157

OL signal waiting time

0 to 25 sec, 9999

0.1 sec

0

124

158

AM terminal function selection

1 to 3, 5 to 14,

1

1

124

 

17, 18, 21

 

 

 

 

 

 

Additional function

160

User group read selection

0, 1, 10, 11

1

0

125

 

 

 

 

 

 

 

 

restartAutomaticafter instantaneouspower failure

162

Automatic restart after instantaneous

0, 1, 2

1

0

125

power failure selection

 

 

 

 

 

163

First cushion time for restart

0 to 20 sec

0.1 sec

0 sec

125

 

 

 

 

 

 

 

 

 

164

First cushion voltage for restart

0 to 100%

0.1%

0%

125

 

 

 

 

 

 

 

 

*165

Restart stall prevention operation level

0 to 150%

0.1%

150%

125

 

 

 

 

 

 

 

Initial monitor

171

Actual operation hour meter clear

0

⎯⎯

0

126

 

170

Watt-hour meter clear

0

⎯⎯

0

126

 

 

 

 

 

 

 

functions

173

User group 1 registration

0 to 999

1

0

125

 

 

174

User group 1 deletion

0 to 999, 9999

1

0

125

User

175

User group 2 registration

0 to 999

1

0

125

176

User group 2 deletion

0 to 999, 9999

1

0

125

 

180

RL terminal function selection

0 to 99, 9999

1

0

126

functions

181

RM terminal function selection

0 to 99, 9999

1

1

126

182

RH terminal function selection

0 to 99, 9999

1

2

126

 

 

183

RT terminal function selection

0 to 99, 9999

1

3

126

assignment

184

AU terminal function selection

0 to 99, 9999

1

4

126

*185

JOG terminal function selection

Already Assigned

 

 

126

 

 

 

 

186

CS terminal function selection

0 to 99, 9999

1

6

126

 

190

RUN terminal function selection

0 to 199, 9999

1

0

128

Terminal

191

SU terminal function selection

0 to 199, 9999

1

1

128

192

IPF terminal function selection

0 to 199, 9999

1

2

128

 

 

193

OL terminal function selection

0 to 199, 9999

1

3

128

 

194

FU terminal function selection

0 to 199, 9999

1

4

128

 

195

A, B, C terminal function selection

0 to 199, 9999

1

99

128

Additional function

199

User's initial value setting

0 to 999, 9999

1

0

130

 

 

 

 

 

 

 

 

Pr.185 : This terminal is already assigned in Factory. User can not use.

21

Page 31
Image 31
Mitsubishi Electronics FR-A500L instruction manual 173