INSTALLATION AND WIRING

 

(1) Description of main circuit terminals

 

 

 

 

 

 

Type

Symbol

Terminal Name

Description

 

 

 

 

 

 

 

R, S, T

AC power input

Connect to the commercial power supply. Keep these terminals unconnected when

 

 

<L1, L2, L3>

using the high power factor converter (MT-HC).

 

 

 

 

 

U, V, W

Inverter output

Connect a three-phase squirrel-cage motor.

 

 

 

 

Connected to the AC power supply terminals R and S. To retain the alarm display

 

 

R1, S1

Power supply for

and alarm output or when using the high power factor converter (MT-HC), remove

 

 

<L11, L21>

control circuit

the jumpers from terminals R-R1 and S-S1 and apply external power to these

 

 

 

 

terminals.

 

Main

P, N

Optional converter

Connect the optional power return converter (MT-RC) or high power factor converter

 

<+,->

connection

(MT-HC).

 

circuit

 

P, P1

DC reactor

Connect the enclosed DC reactor. (375, 450K)

 

 

 

 

connection

DC reactor is prewired in 530-900K sizes.

 

 

 

 

 

P, PR

Brake resistor

Connect the optional FR-BR5 brake resistor.

 

 

<+, PR>

connection

 

 

 

 

 

 

Ground

For grounding the inverter chassis. Must be earthed.

 

 

 

 

 

 

Note:<

>Terminal names in parentheses are those of the EC version.

 

(2) Description of control circuit terminals

Type

Input signals

e.g. start, function setting

 

Contacts,

 

 

Symbol

Terminal Name

Description

 

 

 

Turn on the STF signal to start forward rotation and turn it off to

When the STF

STF

Forward rotation start

stop. Acts as a programmed operation start signal in the

and STR signals

programmed operation mode. (Turn on to start and turn off to

are turned on

 

 

 

 

stop.)

simultaneously,

 

 

Turn on the STR signal to start reverse rotation and turn it off to

the stop

STR

Reverse rotation start

command is

stop.

 

 

 

given.

STOP

Start self-holding

Turn on the STOP signal to select the self-holding of the start signal.

selection

 

 

 

RHRMRL

Multi-speed selection

Use the RH, RM and RL signals as appropriate to select multiple

 

speeds.

Input terminal

 

 

 

 

This terminal connected internally, can not be used by the

(JOG)

JOG mode selection

function selection

customer. (530-900KW:this signal is assigned in Factory.)

 

 

(Pr. 180 to

 

 

Turn on the RT signal to select the second acceleration/

 

 

Pr. 186) change

 

Second acceleration/

deceleration time. When the second functions such as "second

terminal

RT

deceleration time

torque boost" and "second V/F (base frequency)" functions have

functions.

 

selection

been set, these functions can also be selected by turning on the

 

 

 

RT signal.

 

 

 

Turn on the MRS signal (20ms or longer) to stop the inverter output.

 

MRS

Output stop

Used to shut off the inverter output to bring the motor to a stop by the magnetic

 

 

brake.

 

RES

Reset

Used to reset the protective circuit activated. Turn on the RES signal for more than

0.1 sec, then turn it off.

 

 

 

 

AU

Current input

Only when the AU signal is turned on, the inverter can be

Input terminal

 

selection

operated with the 4-20mADC frequency setting signal.

function selection

 

Automatic restart after

With the CS signal on, restart can be made automatically when

(Pr. 180 to Pr.

 

186) change

CS

instantaneous power

the power is restored after an instantaneous power failure. Note

terminal

that this operation requires restart parameters to be set. When

 

failure selection

functions.

 

the inverter is shipped from the factory, it is set to disallow restart.

 

 

 

 

SD

Contact input

Common terminal for the terminal FM.

 

common (sink)

Common output terminal for 24VDC 0.1A power (PC terminal).

 

 

 

 

 

 

 

24VDC power and

When transistor output (open collector output), such as a programmable controller, is

 

external transistor

connected, connect the external power supply common for transistor output to this

PC

common

terminal to prevent a fault caused by leakage current. This terminal can be used as a

 

Contact input

24VDC, 0.1A power output. When source logic has been selected, this terminal

 

common (source)

serves as a contact input common.

 

 

 

 

 

6

Page 14
Image 14
Mitsubishi Electronics FR-A500L Description of main circuit terminals, Description of control circuit terminals, Type