CiM-25/600L IP Enabled M&C

Rev. 1

SNMP Interface

CD/CIM25600L.IOM

A.6.103

ODUVOLTAGE

 

 

 

 

 

 

 

Name

oduVoltage

 

 

OID

1.3.6.1.4.1.6247.21.1.8.9

 

 

Full path

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtech(6247)

 

 

 

.cdm600l(21).cdm600lObjects(1).statusParameters(8).oduVoltage(9)

 

 

Module

CDM600L

 

 

Parent

statusParameters

 

 

Prev sibling

oduCurrent

 

 

Next sibling

oduPhaseLockLoop

 

 

Type

OBJECT-TYPE

 

 

Numerical syntax

SNMP_SYNTAX_INT

 

 

Base syntax

INTEGER

 

 

Composed syntax

INTEGER

 

 

Status

current

 

 

Max-access

read-only

 

 

Size list

 

 

 

1

0..640

 

 

Units

volts

 

 

Description

ODU Voltage. Value multiplied by 10. (ODV?)

A.6.104

ODUPHASELOCKLOOP

 

 

 

 

 

 

Name

oduPhaseLockLoop

 

 

OID

1.3.6.1.4.1.6247.21.1.8.10

 

 

Full path

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtech(6247)

 

 

 

.cdm600l(21).cdm600lObjects(1).statusParameters(8).oduPhaseLockL

 

 

 

oop(10)

 

 

Module

CDM600L

 

 

Parent

statusParameters

 

 

Prev sibling

oduVoltage

 

 

Next sibling

oduOutputPowerLevel

 

 

Type

OBJECT-TYPE

 

 

Numerical syntax

SNMP_SYNTAX_INT

 

 

Base syntax

INTEGER

 

 

Composed syntax

INTEGER

 

 

Status

current

 

 

Max-access

read-only

 

 

Value list

 

 

 

1

locked(0)

 

 

2

unlocked(1)

 

 

Description

Outdoor Unit Phase Lock Loop. (OLL?)

117

Page 135
Image 135