Mocomtech IP-Enabled M&C, CiM-25/600L operation manual Txdatainv, Rxparameters

Models: IP-Enabled M&C CiM-25/600L

1 152
Download 152 pages 48.45 Kb
Page 93
Image 93

CiM-25/600L IP Enabled M&C

Rev. 1

SNMP Interface

CD/CIM25600L.IOM

A.6.31

TXDATAINV

 

 

 

 

 

 

 

Name

txDataInv

 

 

OID

1.3.6.1.4.1.6247.21.1.3.11

 

 

Full path

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtech(6247)

 

 

 

.cdm600l(21).cdm600lObjects(1).txParameters(3).txDataInv(11)

 

 

Module

CDM600L

 

 

Parent

txParameters

 

 

Prev sibling

txCarrierState

 

 

Type

OBJECT-TYPE

 

 

Numerical syntax

SNMP_SYNTAX_INT

 

 

Base syntax

INTEGER

 

 

Composed syntax

INTEGER

 

 

Status

current

 

 

Max-access

read-write

 

 

Value list

 

 

 

1

normal(0)

 

 

2

inverted(1)

 

 

Description

Invert Tx Data. (ITD?, ITD=)

A.6.32

RXPARAMETERS

 

 

 

 

 

 

 

Name

rxParameters

 

 

OID

1.3.6.1.4.1.6247.21.1.4

 

 

Full path

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtech(6247)

 

 

 

.cdm600l(21).cdm600lObjects(1).rxParameters(4)

 

 

Module

CDM600L

 

 

Parent

cdm600lObjects

 

 

Prev sibling

txParameters

 

 

Next sibling

interfaceParameters

 

 

Child

rxFrequency

 

 

Type

OBJECT-IDENTIFIER

75

Page 93