Mocomtech IP-Enabled M&C, CiM-25/600L operation manual RP string

Models: IP-Enabled M&C CiM-25/600L

1 152
Download 152 pages 48.45 Kb
Page 49
Image 49

CiM-25/600L IP Enabled M&C

Rev. 1

Operation

CD/CIM25600L.IOM

3.5.1.8CHANGE READ ONLY PASSWORD

Using the !RP command, the Administrator can change the Read/Only login Password. The command protocol for this command is as follows:

Format:

 

!RP <string>

Where:

 

<string> can be any alphanumeric string of length 4 to 10 characters

Query Format:

!RP ?

Response:

 

!RP <string>

Note:

Changes made via this command do not become active until the user has sent a !EE

 

command to commit the changes to EEPROM of the CiM-25.

3.5.1.9ENABLE OR DISABLE PING

Using the !PG command, the Administrator can either enable or disable PING. The command protocol for this command is as follows:

Format:

 

!PG <state>

Where:

 

0 = Disabled, 1 = Enabled

Query Format:

!PG ?

Response:

 

!PG <state>

Note:

Changes made via this command do not become active until the user has sent a !EE

 

command to commit the changes to EEPROM of the CiM-25.

3.5.1.10COMMIT CHANGES TO EEPROM

Using the !EE command, the Administrator can commit any previously commanded changes to EEPROM. This will store the new operating parameters and automatically do a warm reboot of the CiM-25/600L. The command protocol for this command is as follows:

Format: !EE