HBDV7 Series Direct Vent Gas Fireplace

Optional top vent application

The appliance is shipped as a rear vent unit. If the installa- tion layout requires the unit to be a top vent configuration the appliance can be converted by following the steps below.

Note: Remove and discard top box and insu- lation on top of the unit between the stand- offs. This box is only utilized with rear-vent applications.

OPTIONAL TOP VENT APPLICATION

WARNING

After conversion to top vent configuration,

the 4” (102 mm) flue pipe should be

 

 

concentric within the 6B\,” (175 mm) outer

 

collar (within 1/4”)

 

 

2.Set the flue pipe adapter aside, complete with the gasket. Do not damage the gaskets as the adapter and gasket must be refitted.

3.Remove the eight (8) screws securing the flue pipe cover to the top of the intake box and remove the cover and gasket. Figure 8

4.Remove the six (6) screws securing the flue pipe to the back of the intake box and remove the pipe and gasket.

Figure 9

HBDV300

HBDV400

 

FP2584

Figure 7 -

 

Remove Top Box and Insulation

When removing and refitting the plates and adapter be sure the associated gaskets are undamaged and refitted as required.

1.Remove the eight (8) screws securing the flue pipe adapter to the fireplace body. Figure 8

Screws

Flue Pipe

Cover

Flue Cover

Screws

FP1992

Flue Pipe

Figure 9 -

Remove Flue Pipe

5.Replace flue pipe to top of firebox. Ensure the gasket is in place and undamaged. Secure with six (6) screws. Figure 10

6.Place the flue pipe cover and gasket removed in step 3 over the flue opening in back of the intake box.

7.Refit the flue pipe adapter and gasket to the top of fire- place. Secure the adapter with eight (8) screws removed in step 1.

Flue Pipe

Screws

Flue Pipe

Figure 10 -

FP1993

Figure 8

-

Adapter

FP1991

Remove

16 Screws from Flue Pipe Adapter

 

and Flue Pipe Cover

Attach Flue Pipe to Top Vent Configurations

10

54D8000

Page 10