HBDV7 Series Direct Vent Gas FireplaceSIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS

FUNCTIONS/OPERATION

Turning on the fireplace

1.Turn on the master switch and wait for a beep.

2.Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on High set- ting or last memory setting (See Turning Off Fireplace below). For memory feature.

Pilot Safety Lockout Function

1.If the pilot doesn’t light after sparking for 30 seconds, pilot trial lockout happens. The LED on the Command Center flashes Green once every 2 seconds, until reset.

2.If the pilot flame is lost during normal operation, the system will try three (3) times to relight after three (3) failures, flame loss lockout happens. The LED on the Command Center flashes Red-Green once every 2 seconds, until re- set.

3.Turning the master switch on the Command Center to the off position, then ON again will reset the system.

Flame Height Control

1.Press the ON button (on the Command Center) once to turn on the main burner with maximum flame height.

2.Press the OFF button to decrease flame height. The first two presses will decrease the flame height to medium and low.

3.The third press on OFF will turn off the main burner. In standing pilot configuration, the pilot will stay; in intermittent pilot configuration, the pilot will be shut off.

Turning the Fireplace Off

There are three ways to turn the fireplace off.

1.Flip the master switch to the off (“O”) position. (This will turn the entire system OFF.)

2.Press the OFF button to Medium, Low, then Off.

3.Hold the OFF button anytime for three seconds or by turning off the wall switch. These two commands of OFF are (Memory Off) the system will remember all last settings before turning off. The next time the fireplace is turned on, all settings will resume. To reset, change to the desired settings and shut off by using the Memory Off commands and the system will be reset to those new settings.

Command Center Operations:

The following functions are available on the Command Center.

Function

operation

Power Up

Flip the master switch to the ON ("_") position to power up the system

Fireplace ON

Press the ON button on the Command Center or turn on wall switch to turn the fireplace on

Fireplace OFF

Flip the master switch to the OFF ("o") position OR press the OFF button 3

 

times OR for Memory Off, hold the OFF button 3 seconds, or turn off wall switch

Flame Height Up

Press the ON button once to turn on the fireplace with maximum flame height

Flame Height Down

Press the OFF button to lower the flame height to Medium and Low

 

 

Self Diagnostics Chart:

The Command Center has a self-diagnostic LED enabling you to troubleshoot problems and potentially avoid a ser- vice call. Please refer to the charts below for indicator reference.

Fault

leD Indication

Conversion Cover Missing

One RED (1 time)

Spark Fail

Two RED (1 time)

No Sensor Signal

Three RED (1 time)

Pilot Lockout - trial

One GREEN, every 2 sec. (until manual reset)

Pilot Lockout - flame loss

One RED-GREEN, every 2 sec. (until manual reset)

Low Battery

One RED, every 10s (continuously)

No or Low Thermopile Power

Two RED, every 10s (continuously)

Learning

GREEN Flashes, every 1 sec. (for 10 sec.)

AC Power On

GREEN solid

Pressure Switch Failed (Power Vent only)

One RED every 2 sec. (until manual reset)

 

 