SECURE FIREPLACE TO FLOOR or FRAMING | HBDV7 Series Direct Vent Gas Fireplace |
The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side nailing flanges are 1/2" or 5/8" to accommodate different wall thickness.
Framing
WARNING | DO NOT REMOVE | Insulation | |
Board | |||
BOARD | |||
| INSULATION |
| |
|
|
|
Screws
Nailing Flange
Screws
Figure 6 -
Secure Fireplace to Floor and Framing Studs
Screws
Finishing Material
NOTE: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to final finishing to avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating of Zero) may be used to cover the black surface of the appliance. A 300°F minimum adhesive may be used to attach facing materials to the black surface. If joints between the finished wall and the fireplace surround are sealed, a 300°F minimum sealant material (General Electric RTV103 or equivalent) must be used.