Monessen Hearth HBDV300N/PSC7 Electrical Wiring, General, Optional Accessory Requirements, leaks

Models: HBDV300N/PV7 HBDV400N/PSC7 HBDV300N/PSC7 HBDV400N/PV7

1 64
Download 64 pages 47.51 Kb
Page 31
Image 31
General

SIGNATURE COMMAND - CHECK GAS PRESSURE and ELECTRICALHBDV7 SeriesINSTALLATIONDirect Vent Gas Fireplace

1.Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately.

2.To ease installation, a 24" (610 mm) flex line with manual shut-off valve has been provided with this ap- pliance. Install and attach 1/2" gas line onto shut-off valve.

3.After completing gas line connection, purge air from gas line and test all gas joints from the gas meter to the fireplace for leaks. Use a solution of 50/50 water and soap solution or a gas sniffer.

4.To check gas pressures at valve, turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point. Turn unit to high. Figure 52. After taking pressure reading, be sure and turn captured screw clockwise firmly to reseal. Do not over torque. Check test points for gas leaks.

Electrical Wiring

General

1.This fireplace is equipped with the Signature Control valve which operates on 6 volts. The 6 volt DC adapter plugs into the fireplace junction box A/C power supply. Four (4) “AA” batteries are used for back up during power outages.

2.The Signature Command System can also be operated without A/C power. The system can run on four (4) “AA” batteries for approximately six (6) months under normal use.

3.A/C power must be used to power the A/C module, blowers, lights and AUX accessories if used with this fireplace.

Optional Accessory Requirements

1.This fireplace may be used with a wall switch, wall mounted thermostat and/or Signature Command wire- less controls.

2.The command center control may be mounted on the wall with the use of the SCSWEK 15ft. wall mount exten- sion kit.

Pressure Inlet

Pressure Outlet

Pilot Adjust-

ment Screw

 

Figure 52 -

 

Signature Command Valve

 

 

WARNING

Do not use open flame to check for gas

 

 

 

 

leaks.

 

 

 

 

 

Electrical connections should only

 

 

be performed by a qualified, licensed

 

 

electrician. Main power must be off when

 

WARNING

connecting to main electrical power supply

 

or performing service. All wiring shall be

 

 

 

 

in compliance with all local, city and state

 

 

codes. The appliance, when installed, must

 

 

be electrically grounded in accordance with

 

 

local codes or in the absence of local codes,

 

 

with the National Electrical Code ANSI/NFPA

 

 

70 (latest edition) and Canadian Electrical

 

 

Code, CSA C22.1.

 

 

 

 

 

 

 

CAUTION

Label all wires before disconnecting when

 

 

 

 

servicing controls. Wiring errors can cause

 

 

improper and dangerous operation.

 

 

 

54D8000