HBDV7 Series Direct Vent Gas Fireplace

CLEARANCES

Clearances to combustibles

WARNING

Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard.

The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.

Ceiling

 

Combustible

Mantel

 

 

71”

 

 

Minimum

12”

 

 

Minimum

 

NOTE: All mantel shelves, regard-

less of depth, should be a mini- mum of 12” from top of fireplace. Wall

Mantel shelf shall not exceed 12” maximum depth at 12” minimum

height from opening.

12”

12”

12”

Max.

Top of Exhaust

Louvers

Side View

Stud

Insulation

Board

Standoff

FP2581

Min. 4”

From Either

Side Wall

Figure 4 -

Clearances

FP2580

MANTEL CLEARANCES

NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.

WARNING

Never obstruct or modify the air inlet or

 

 

outlet grilles (louvers). This may create a

 

fire hazard.

 

 

 

 

Combustible

 

 

 

Material Area

 

 

 

Wall

 

FP2582

1" 156O

 

 

 

 

256O

256O

 

 

 

45°

 

3"

 

Side of Fire-

 

 

place Opening

 

4"

 

 

Top View

 

Figure 5 -

Mantel Clearances

54D8000

Page 8
Image 8
Monessen Hearth HBDV300N/PV7 Clearances to combustibles, Mantel Clearances, Never obstruct or modify the air inlet or