HBDV7 Series Direct Vent Gas Fireplace

OPTIONAL FAN BLOWER SYSTEMS

WARNING

Electrical Grounding Instructions: This

appliance is equipped with a three-prong

 

 

(grounding) plug for your protection against

 

shock hazard and should be plugged directly

 

into a properly grounded three-prong

 

receptacle.

 

 

 

 

 

The black and white wires on the AC box

NOTE

wiring harness are marked ‘Blower’, ‘Light’

and ‘Aux’. It is important to use the wires

marked ‘Blower’ or the control will not work

 

correctly.

 

 

WARNING

Electrical connections should only be performed by a qualified licensed electrician. Main power supply must be turned off before connecting the fan to the main electrical power supply or performing service.

BLOTSC SIGNATURE COMMAND BLOWER

To Junction Box

 

In Fireplace

 

 

Optional AC

Optional

Module

Light

{ WHITE

WHITE

BLACK

 

BLACK

BLACK

Optional

{ WHITE

AUX

Blower (300w Max)

GREEN

Connector

 

 

Pin To Control Box

Figure 55 -

 

Blower Wiring Diagram

 

Control Box

The BLOTSC Blower Kit requires the SCSACM A/C Mod-

ule and the TSFSC remote to install and operate this kit.

Refer to blower instructions for installation.

 

FP2103