Motorola 3397GP manual Sleep Contact-email string@domainname location string, 212

Models: 3397GP

1 262
Download 262 pages 31.83 Kb
Page 212
Image 212

Administrator’s Handbook

set system heartbeat option { on off } protocol [ udp tcp ]

port-client [ 1 - 65535 ]

ip-server [ ip_address dns_name ] port-server [ 1 - 65535 ] url-server ("server_name") number [ 1 – 1073741823 ] interval (00:00:00:20)

sleep (00:00:30:00)

contact-email ("string@domain_name") location ("string"):

The heartbeat setting is used in conjunction with the configuration server to broadcast contact and location information about your Gateway. You can specify the protocol, port, IP-,port-, and URL- server.

The interval setting specifies the broadcast update frequency. Part of sequence control. The inter- val is the spacing between heartbeats, in d:h:m:s.

The contact-emailsetting is a quote-enclosed text string giving an email address for the Gateway’s administrator.

The location setting is a text string allowing you to specify your geographical or other location, such as “Secaucus, NJ.”

The number setting is part of the sequence control. This is the number of heartbeats to send, at each “interval”, before sleeping. For example, if this is 20, in the above layout, each heartbeat sequence will send out a total 20 heartbeats, spaced at 30 second intervals, and then sleep for 30 minutes. So to have the Gateway send out packets “forever”, this number can be set very high. If it is 1440 and the interval is 1 minute, say, the heartbeat will go out every minute for 1440 minutes, or one day, before sleeping.

The sleep setting is part of sequence control. This is the time to sleep before starting another heartbeat sequence, in d:h:m:s.

set system ntp option [ off on ]:

server-address (north-america.pool.ntp.org) alt-server-address (pool.ntp.org): time-zone [ -12 - 12 ]

update-period (60) [ 1 - 65535 ]: auto-daylight-savings option [ off on ] auto-daylight-savings override option [ off on ]

start-year [ 0 - 99 ] start-month [ 1 - 12 ] start-day [ 1- 31 ] start-hour [ 0 - 23 ] end-year [ 0 - 99 ] end-month [ 1 - 12 ] end-day [ 1 - 31 ] end-hour [ 0 - 23 ]

Specifies the NTP server address, time zone, and how often the Gateway should check the time from the NTP server. The NTP server-addressand alt-server-addresscan be entered as DNS names as well as IP addresses. NTP time-zone of 0 is GMT time; options are -12 through 12 (+/- 1 hour incre- ments from GMT time). update-periodspecifies how often, in minutes, the Gateway should update the

212