INSTALLATION

 

Fuse

 

 

 

(10 A)

 

 

 

Fuse Holder

 

 

 

Adapter

Cover

 

 

 

 

 

Red Lead

 

 

 

Red Lead

Red Lead

 

 

(min. 2.5 mm2)

 

 

2

)

 

Mounting Hole

(min. 2.5 mm

 

 

 

 

 

Ring Lugs

 

 

Black Lead

 

 

 

(min. 2.5 mm2)

 

 

 

To Battery -

To Battery +

 

 

or Chassis

 

 

Figure 2 Power Cable Assembly

5.Place the fuse holder close to the battery. Ensure that it is not near any hot engine component. Mount the fuse holder using its mounting hole and dress the wires as required.

6.Insert the stripped end of the red lead of the fuse holder into the ring lug hole and crimp it. Connect the fuse holder red adapter lead plug to the mating receptacle on the red lead of the power cable.

7.Connect the red lead ring lug from the fuse holder to the positive (+) battery terminal. Make sure the adapter cable is connected to the main power cable red lead.

8.Carefully check that all connections are proper. Insert the fuse into the fuse holder and close the cover.