40 | MTM5400 Mobile Terminal Installation Manual | INSTALLATION |
Remote Mount Installation
Transceiver
Remote Mount Cable
Remote Head
Enhanced
or
Data Expansion
Head Enhanced
Remote Mount Enhanced
Control Head
Figure 10 Remote Mount Installation with Remote Head Enhanced/Data Expansion Head Enhanced
Table 4 Associated Components for Remote Mount
Item | Description | Part Number |
|
|
|
1 | Remote Mount Cable, 3 m | RKN4077 |
|
|
|
2 | Remote Mount Cable, 5 m | RKN4078 |
|
|
|
3 | Remote Mount Cable, 7 m | RKN4079 |
|
|
|
4 | Remote Mount Cable, 10 m | PMKN4020 |
|
|
|
5 | Remote Head Enhanced | PMLN4904 |
|
|
|
6 | Data Expansion Head Enhanced | PMLN4908 |
|
|
|
Enhancement |
| |
|
|
|
7 | Toroid EMC Suppression Kit | 01015001001 |
|
|
|
When toroids are used on the Remote Mount Cable, wind 10 times around each toroid.
Each toroid have to be placed 30.0±2.5 cm respectively from the expansion head and the control head.
Winding at both ends reduces the effective cable length approximately by 0.8 m. Fix the toroids firmly to a stable surface once the Remote Mount Cable is connected.