40

MTM5400 Mobile Terminal Installation Manual

INSTALLATION

Remote Mount Installation

Transceiver

Remote Mount Cable

10-Pin Connector

Remote Head

Enhanced

or

Data Expansion

Head Enhanced

10-Pin Connector

Remote Mount Enhanced

Control Head

Figure 10 Remote Mount Installation with Remote Head Enhanced/Data Expansion Head Enhanced

Table 4 Associated Components for Remote Mount

Item

Description

Part Number

 

 

 

1

Remote Mount Cable, 3 m

RKN4077

 

 

 

2

Remote Mount Cable, 5 m

RKN4078

 

 

 

3

Remote Mount Cable, 7 m

RKN4079

 

 

 

4

Remote Mount Cable, 10 m

PMKN4020

 

 

 

5

Remote Head Enhanced

PMLN4904

 

 

 

6

Data Expansion Head Enhanced

PMLN4908

 

 

 

Enhancement

 

 

 

 

7

Toroid EMC Suppression Kit

01015001001

 

 

 

When toroids are used on the Remote Mount Cable, wind 10 times around each toroid.

Each toroid have to be placed 30.0±2.5 cm respectively from the expansion head and the control head.

Winding at both ends reduces the effective cable length approximately by 0.8 m. Fix the toroids firmly to a stable surface once the Remote Mount Cable is connected.

Page 40
Image 40
Motorola MTM5400 installation manual Remote Mount Installation, Associated Components for Remote Mount